background image

 

more than 40 feet (12 meters) long. 

6.  Install a detector inside every room where one sleeps with the door partly or 

completely closed, since smoke could be blocked by the closed door and a 
hallway alarm may not wake up the sleeper if the door is closed. 

7.  Install detectors as close to the center of the ceiling as possible.    If this is 

not practical, put the detector on the ceiling, no closer than 4 inches (10 cm) 
from any wall or corner as shown in FIGURE 4. 

                                                                       

 
 
 
 
 
 
 
 
 
 
 

8.  If  ceiling  mounting  is  not  possible,  put  wall-mounted  detectors  between  4 

and 6 inches (10~15 cm) from the ceiling (FIGURE 4). 

9.  If some of your rooms have sloped, peaked, or gabled ceilings, try to mount 

detectors 3 feet (0.9 meter) measured horizontally from the highest point of 
the ceiling as shown in FIGURE 5. 

 
 
 
 
 
                                                                           
 
 
 

 

Locations Not To Install the Detector 
 

Nuisance alarms take place when smoke detectors are installed where they will 
not work properly.    To avoid nuisance alarms, do not install smoke detectors in 
the following situations: 
 

1.  Combustion  particles  are  the  by-products  of  something  that  is  burning.   

Thus,  in  or  near  areas  where  combustion  particles  are  present  you  do  not 
install the smoke detectors to avoid nuisance alarms, such as kitchens with 
few  windows  or  poor  ventilation,  garages  where  there  may  be  vehicle 
exhaust, near furnaces, hot water heaters, and space heaters. 

2.  Do not install smoke detectors less than 20 feet (6 meters) away from places 

where combustion particles are normally present, like kitchens.    If a 20-foot 
distance is not possible, e.g. in a mobile home, try to install the detector as 
far away from the combustion particles as possible, preferably on the wall.   
To prevent nuisance alarms, provide good ventilation in such places. 

 
IMPORTANT

: For any reason, do not disable the detector to avoid nuisance 

alarms. 
 

3.  When  air  streams  passing  by  kitchens,  the  way  how  a  detector can  sense 

combustion  particles  in  normal  air-flow  paths  is  graphically  shown  in 
FIGURE  6,  which  indicates  the  correct  and  incorrect  smoke  detector 
locations concerning this problem. 

 
 
 
 
 
 
 
 
 
 
 
 
4.  In damp or very humid areas, or near bathrooms with showers.    Moisture in 

humid  air  can  enter  the  sensing  chamber,  then  turns  into  droplets  upon 
cooling, which can cause nuisance alarms.    Install detectors at least 10 feet 
(3 meters) away from bathrooms. 

5.  In  very  cold  or  very  hot  areas,  including  unheated  buildings  or  outdoor 

rooms.    If  the  temperature  goes  above  or  below  the  operating  range  of 
smoke  detector, it  will  not  work  properly.    The temperature  range for  your 
smoke detector is 4

°

C to 38

°

C (40

°

F to 100

°

F). 

6.  In  very  dusty  or  dirty  areas,  dirt  and  dust  can  build  up  on  the  detector

’s 

sensing chamber, to make it overly sensitive.    Additionally, dust or dirt can 

FIGURE 4 

Recommended  best  and 
acceptable  locations  to 
mount smoke detectors.

 

FIGURE 5 

Recommended  location  to 
mount  smoke  detectors  in 
rooms  with  sloped,  gabled 
or peaked ceiling.

 

FIGURE 6 

Recommended  smoke  detector  locations 
to  avoid  air  streams  with  combustion 
particles.

 

Содержание SHD1115

Страница 1: ...there is a link key which is used to carry out the function of inclusion exclusion association and reset When first power is applied its LED flashes on and off alternately and repeatedly for 4 minutes which implies that it has not been assigned a node ID and cannot work with Z Wave enabled devices Please get familiar with the terms below before starting the operations Function Description Inclusio...

Страница 2: ...esidents In multi family buildings each family living unit should set up its own detectors The detector is not meant to be used in non residential buildings Warehouses industrial or commercial buildings and special purpose non residential buildings require special fire detection and alarm systems This detector is not a suitable substitute for complete fire detection systems for places where many p...

Страница 3: ... feet 6 meters away from places where combustion particles are normally present like kitchens If a 20 foot distance is not possible e g in a mobile home try to install the detector as far away from the combustion particles as possible preferably on the wall To prevent nuisance alarms provide good ventilation in such places IMPORTANT For any reason do not disable the detector to avoid nuisance alar...

Страница 4: ...Installation 1 At the place where you are going to install the detector draw a horizontal line six inches long 2 Remove the mounting bracket from the detector by rotating it counterclockwise FIGURE 7 FIGURE 7 3 Place the bracket so that the two longest hole slots are aligned on the line In each of keyhole slots draw a mark to locate a mounting plug and screw 4 Remove the bracket 5 Using a 3 16 inc...

Страница 5: ...will emit when event occurs 1 1 POWER_APPLIED command The Smoke Detector will send ALARM_REPORT command to the nodes of Grouping 1 to inform the devices that the detector is powered up ALARM_REPORT Command Command Class Alarm Alarm Type 0x02 Alarm Level 0x01 1 2 Smoke Event Report Once the detector has been triggered by smoke the detector will send SENSOR_ALARM_REPORT Sensor State 0xFF to the node...

Страница 6: ...tector is out of order Remove the battery press link key several times to release the existing battery power and wait for approx 10 seconds before replacing the battery Specifications Operating Frequency 868 42 MHz SHD1115 1 908 42 MHz SHD1115 2 Battery Type 9V alkaline battery x 1 Operating Range Up to 30 meters line of sight indoor ZDK Version V5 02 Specifications are subject to change without n...

Страница 7: ...not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances wit...