Chapter 3 Status
P-974H/HW Series User’s Guide
41
ToD request
sent - No
Response
received
Warning
Your ZyXEL Device sent a request to the time-of-day (ToD) server
specified by the DHCP server, but it did not receive a reply within the
specified timeout period. Your ZyXEL Device defaults to setting its
onboard clock to midnight on January 1, 1970. Your ZyXEL Device
can now proceed with the registration process without receiving a
ToD response, but will continue trying to contact the ToD server
every 5 minutes until it receives a valid response.
ToD Response
received -
Invalid data
format
Warning
Your ZyXEL Device received a reply from the ToD server that was
specified by the DHCP server. The reply from the ToD server was
either an empty datagram or it contained invalid data (the ToD
server should send a reply that contains only one 32-bit number that
indicates the number of seconds since midnight on January 1, 1900).
Please refer to RFC 868, Time Protocol for additional information.
The DOCSIS specifications do not allow the use of the Network Time
Protocol (NTP) or Simple Network Time Protocol (SNTP) ToD servers
to set your ZyXEL Device’s system time.
UCC- REQ
received with
invalid or out of
range US
channel ID
Error
Your ZyXEL Device has received an Upstream Channel Change
Request (UCC-REQ) message from your cable operator’s CMTS that
contains an upstream channel ID that is either invalid or out of
range.
UCC- REQ
received unable
to send UCC-
RSP, no TX
opportunity
Error
Your ZyXEL Device has received an Upstream Channel Change
Request (UCC-REQ) message from your cable operator’s CMTS, but
could not reply with an UCC Response message (UCC-RSP) because
it could not obtain a transmit timeslot.
US channel wide
parameters not
set before Burst
Descriptors
Critical
Your ZyXEL Device has received an Upstream Channel Descriptor
(UCD) message from the CMTS, but it did not set the channel and
symbol rate parameters before beginning the set of TLVs (Type
Length Value) that specify the burst descriptors for the upstream
channel. TLVs are an encoding for three fields: the first field is the
type of element, the second field is the length of the element, and
the third filed is the value of the element.
UCD & SYNC
valid - NO MAPS
for this channel
Critical
Your ZyXEL Device has received valid Upstream Channel Descriptor
(UCD) and SYNC messages from the CMTS, but the upstream
channel that is specified in the UCD does not offer your ZyXEL
Device any MAP (one slot of the Time Division Multiplexing) minislots
in which to transmit.
Table 9
Event Log: Log Description (continued)
LOG NAME
SEVERITY
DESCRIPTION
Содержание P-974H - V3.70
Страница 2: ......
Страница 7: ...Safety Warnings P 974H HW Series User s Guide 7 This product is recyclable Dispose of it properly...
Страница 8: ...Safety Warnings P 974H HW Series User s Guide 8...
Страница 12: ...Table of Contents P 974H HW Series User s Guide 12...
Страница 16: ...List of Tables P 974H HW Series User s Guide 16...
Страница 18: ...18...
Страница 22: ...Chapter 1 Introduction P 974H HW Series User s Guide 22...
Страница 28: ...Chapter 2 The Web Configurator P 974H HW Series User s Guide 28...
Страница 42: ...Chapter 3 Status P 974H HW Series User s Guide 42...
Страница 68: ...Chapter 7 Maintenance P 974H HW Series User s Guide 68...
Страница 70: ...70...
Страница 76: ...Appendix A Product Specifications P 974H HW Series User s Guide 76...
Страница 98: ...Appendix C Setting up Your Computer s IP Address P 974H HW Series User s Guide 98...
Страница 102: ...Appendix D Common Services P 974H HW Series User s Guide 102...
Страница 116: ...Index P 974H HW Series User s Guide 116...