Chapter 7 Maintenance
NSG Series User’s Guide
33
7.3.1 Packet Capture Files Screen
Click
Maintenance > Diagnostics > Packet Capture > Files
to open the packet capture files screen. This
screen lists the files of packet captures stored on the NSG or a connected USB storage device. You can
download the files to your computer where you can study them using a packet analyzer (also known as
a network or protocol analyzer) such as Wireshark.
Save data to USB
storage
Select this to have the NSG store packet capture entries only on a USB storage device
connected to the NSG if the NSG allows this.
Status:
Unused
- the connected USB storage device was manually unmounted by using the
Remove Now
button or for some reason the NSG cannot mount it.
none
- no USB storage device is connected.
service deactivated
- USB storage feature is disabled (in
Configuration > Object > USB
Storag
e), so the NSG cannot use a connected USB device to store system logs and other
diagnostic information.
available
- you can have the NSG use the USB storage device. The available storage
capacity also displays.
Note: The NSG reserves some USB storage space as a buffer.
Capture
Click this button to have the NSG capture packets according to the settings configured
in this screen.
You can configure the NSG while a packet capture is in progress although you cannot
modify the packet capture settings.
The NSG’s throughput or performance may be affected while a packet capture is in
progress.
After the NSG finishes the capture it saves a separate capture file for each selected
interface. The total number of packet capture files that you can save depends on the
file sizes and the available flash storage space. Once the flash storage space is full,
adding more packet captures will fail.
Stop
Click this button to stop a currently running packet capture and generate a separate
capture file for each selected interface.
Reset
Click this button to return the screen to its last-saved settings.
Table 17 Maintenance > Diagnostics > Packet Capture (continued)
LABEL
DESCRIPTION