![ZyTemp TN905-05F Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/zytemp/tn905-05f/tn905-05f_user-manual_943189008.webp)
TN9 Infrared Thermometer Module
http://www.ZyTemp.com
REV. 07/20/2004
3 Specification
3.1 Absolute Maximum Rating
Characteristics
Symbol
Ratings
DC Supply Voltage
V
+
<7.0V
Input Voltage Range
V
IN
-0.5V to V+ + 0.5V
Note:
Stresses beyond those given in the Absolute Maximum Rating table may cause
operational errors or damage to the device. For normal operational conditions see AC/DC
Electrical Characteristics.
3.2 DC Characteristics
(VDD = 3.0V, TA = 25
℃
)
Limit
Characteristics
Symbol
Min
Typ.
Max
Unit
Test condition
Operating Voltage VDD
2.5
-
3.6
V
Operating Current
I
OP
- 4 6
mA
VDD = 3.0V,
F
CPU
= 600KHz
Standby Current
I
STBY
- 2 3
μ
A
VDD = 3.0V
Input High Level
V
IH
2.0
-
-
V
VDD = 3.0V
Input Low Level
V
IL
-
-
0.8
V
VDD = 3.0V
Output High I
I
OH
- -2.0 - mA
VDD = 3.0V, V
OH
= 2.4V
Output Sink I
I
OL
- 2.5 - mA
VDD = 3.0V, V
OH
= 0.8V
(VDD = 4.5V, TA = 25
℃
)
Limit
Characteristics
Symbol
Min
Typ.
Max
Unit
Test condition
Operating Voltage VDD
3.6
-
5.0
V
Operating Current
I
OP
- 6 9
mA
VDD = 4.5V,
F
CPU
= 600KHz
Standby Current
I
STBY
- 3 4.5
μ
A
VDD = 4.5V
Input High Level
V
IH
3.0 - -
μ
A
VDD = 4.5V
Input Low Level
V
IL
- - 0.8
μ
A
VDD = 4.5V
Output High I
I
OH
- -2.0 - mA
VDD = 4.5V, V
OH
= 3.5V
Output Sink I
I
OL
- 2.5 - mA
VDD = 4.5V, V
OL
= 0.8V