Wall Mount CO2 Monitor Operating Instructions 

Model: ZGw08PR 

 

Product Overview 

 

Thank you for selecting ZGw08PR CO2 wall mount monitor. This product was developed to detect 

the presence of CO2 in the ambient air and help people to take care of the Indoor Air Quality. The 

compact device is designed for use in HAVC in the building. The demand controlled ventilation in 

the building, also the greenhouse with the CO2 concentration control. 
By using the CO2 monitor as the indicator, it can easily get the current CO2 concentration together 

with the ventilation rate. And then adjust the ventilation to the comfort condition automatically by the 

setting data. So the over-ventilation of the building can be reduced, and the energy can be saved. 

The ZGw08PR can be widely used in the office building, green house, school, exhibition, shopping 

mall. 
The ZGw08PR is easy to use and has many features: 

 

NDIR ( Non-Dispersive-Infrared) technology used to measure CO2 concentration 

 

Three different LED display show the current Indoor Air Quality situation. 

 

Relay output   

 

Reliable Sensor provides long-term calibration stability. 

 

The visual and audible alarm function can be adjustable by user. 

 

Mounting bracket with terminal block provides quick easy installation. 

Operation Instruction 

 

Front view                                              Back view 
 

 

 
Side view 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

LCD Display Symbol 

 

Safety Instruction 

Warning: Your safety is very important to us .To ensure you use your product correctly and safety, 

we would like to your attention to read those warning and the entire User Manual before using the 

product. These Warnings provide important safety information and should be observed at all times. 
1. Please take the devices lightly, do not subject the product to impact or shock. 

2. Do not immerse the product in water. 

3. Please pay attention to the terminal block connection instruction, the wrong mode of operation or 

opposite installation will destroy the circuit of the devices. 

4. Do not touch the exposed electronic circuitry of the device under any circumstances. Keep the 

circuit is close during installation. As there is the danger of electric shock. 

5. Please keep the devices away from children touch to avoid the dangerous or the accident. 

6. Do not keep the product under the hot and moisture environment. Keep the product away form 

the heat source or near water. 

7. Please use only the included power adaptor. Improper power adaptor or power sources can 

cause serious damage to the product, or result in injury or death to the user. 

8. Please ensure the screws are fixed on the wall tightly. Do not let the screws approach or close to 

the surface of PCB board during installation. It has the risk of circuit damage or irreparable 

damage to device. 

Caring for product 

To make sure you receive the maximum benefit from using this product, please observe the follow 

guideline. 
1. Cleaning —Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning 

agent, such as benzene, thinner or aerosols.           

2. Repair---- Do not attempt to repair the product or modify the circuitry by yourself. Please contact 

with the local dealer or a qualified repairman if the product needs servicing. 

3. Calibration--- Please observe the calibration operation to make sure the accuracy for the devices 

when it’s necessary. 

4. Air circulation---The vents allow the air circulation liquid for measurement of the CO2 

concentration and the ventilation should not be blocked. 

Installation Step 

Step 1: Release the screw from the device, take the front cover off. 

Step 2: Release the four screws from the back cover, take the CO2 board from the back cover. 

Step 3: Using the screw to fix the back cover to the current outlet, let the wires come out of the hole. 

Please pay attention to the terminal block connection data information. 

Step 4: Re-assembling the CO2 board by screw to the back cover. 

Step 5: After finishing the terminal block wire connection. Press the front cover to the LCD display, 

and tighten the Front Cover screw with screwdriver. 

Step 6: Connect the AC adapter with the power inlet. 

 

 

 

 

 

 

 

 

 

 

 

 

   Step 1                   Step 2                 Step3 

 

 

 

 

 

 

 

 

 

 

 

 

      Step 4                                      Step 5 & 6 

Wiring Connection 

Caution: The RJ45 socket is only for factory calibration use, not for LAN, it was covered by plastic 

cover, the incorrect RJ 45 connection will have the risk of circuit damage or irreparable damage 

to devices. 

 

 

 

 

 

 

 

 

Customizing Settings 

When the power has been connected, The ZGw08PR CO2 monitor will begin to work. In order to 

meet you personal requirement, it is advisable to set up the customizing parameter. 
WarmUp: It lasts approximately 1min before WARM UP disappears; all MODE functions will not 
response during warm up. 
Ventilation Rate

 

 

1. Press up/down to choose the ventilation rate modes. 
2. When pressing up button, the LCD display sequence is Vent Rate l/p/s -> Vent Rate cfm/p. When 

pressing down button, The LCD display sequence is reverse. 

A. Main LCD Display 

H. Enter Button 

B. Green LED Display 

( <800ppm) 

I. Screw Position   

C. Yellow LED 

Display 

(800-1200ppm) 

J. Terminal Block for 

Relay Output 

D. Red LED Display 

(>1200ppm) 

K. Power Inlet for AC 

adapter(6VDC) 

E. Mode Button 

L. RJ 45 Socket 

(For factory use 

only)

 

F. Up Button 

M. Gas Entry Hole 

G. Down Button 

 

 

 

 

Symbol Meaning

 

Description

 

 

CO2 Concentration PPM 
Parts Per Million 

The current CO2 concentration in your 
household. 

 

Ventilation Rate cfm/p   
Cubic Feet 
Minute/Person 

The Present Cubic Feet/Minute Ventilation for 
one person. 

 

Ventilation Rate L/P/S 
Liter/Person/Second 

The Current Liter/ Second Ventilation Rate for 
one person. 

 

Alarm 

The Alarm Setting Icon,the factory setting with 
alarm is buzzer off 

 

Calibration 

To calibration the CO2 sensor when the accuracy 
deviates from the actual CO2 concentration. 

 

Alarm Level 1 

The 1

st

 Alarm Level. 

Relay status will invert after CO2 level exceeds 
AL1 
The Buzzer and Yellow LED will work after CO2 
level exceeds AL1 

 

Alarm Level 2 

The 2

nd

 Alarm Level   

The Buzzer and Red LED will work after CO2 
level exceeds AL2 

 

Recover Factory Setting 

To Recover Factory Setting to cancel the 
customize Setting 

RS232

TX

RX

2. Relay Common

1. Relay Norm Open

M

L

K

J