ZUWA Impeller Pumps
12
Caution
Motor damage can arise due to unsuitable extension cable
>
For extension cables of length up to 20 metres: Use cables with at
least the same cross section as the pump cable.
>
For extension cables with a length of more than 20 metres: Use
cables with a larger cross section than the pump cable.
6.2.2 Series 2001-A, 2001-B und 2001-C
The pumps can, for example, be driven with the following drive systems:
power drill
V-belt drive
gear motor
hydraulic motor
pneumatic motor
Ensure correct speed and output of the drive system:
Max. speed 3000 rpm
Minimum output of the drive system:
-
370 Watt for types of series 2001-A
-
550 Watt for types of series 2001-B
-
1100 Watt for types of series 2001-C
When using external drive systems,
observe the manufacturer’s
instructions.
Impeller pumps require an increased
starting torque.
For pumps with three-phase motor,
observe the direction of rotation of the
motor. The direction of rotation is indicated
by an arrow on the type plate.