- 10 -
Figure 3-1 Measuring Loop Circuit Current
1. turn the rotary switch to
“ ””
, and the screen displays
“
LOOP POWER
”
;
2. insert black probe into
“
mA
””
terminal ,and insert red
probe into
“
+LOOP
”
terminal;
3. Connect the probes to the circuit under test and then
read the measured value when stable.
4. Press button to display current value in
percentage form.
Measuring loop-circuit current with 250
Ω
HART
resistance
1. turn the rotary switch to
“
”
, and the screen displays
“
LOOP POWER
”
and
“
250
Ω
HART
”
;
2. insert black probe into
“
mA
””
terminal ,and insert red
probe into
“
+LOOP
”
terminal;
3. Connect the probes to the circuit under test and then
read the measured value when stable.
4. Press button to display current value in
percentage form.
Using current output function
The meter offers 0-20 mA and 4-20mA current output
functions.
Two output modes:
SOURCE mode: supply current from internal source;
SIMULATE mode (simulate): absorb current from
external source
Two Configuration modes:
Constant current output: constant output of designated
current.
Manual-step output: output current increases or
decreases in 25% or 100% step.
If you need to apply current for non-source circuit
(such as loop current without power), then select
SOURCE mode. The meter consumes more battery
power of being used as current source than that of being
used in SIMULATE mode, so select SIMULATE mode if
possible.