ZS880

LINEAR SHOWER DRAIN INSTALLATION INSTRUCTIONS

Zurn Industries, LLC

 

|

 

Specification Drainage Operation

1801 Pittsburgh Avenue, Erie, PA  U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929
In Canada

 

|

 

Zurn Industries Limited

3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292

www.zurn.com

®

Rev.

-

Date:

4/23/2018

C.N. No.

139950

Form No. FT1009

Page 3 of 6

Dimensional data (inches and [mm]) are subject to manufacturing tolerances and change without notice.

Adjusting the Tiling Frame

Each shower drain is provided with a series of #10-24 x 7/8 flat head hex socket screws that thread into sealed blind-hole
inserts, which are crimped to the shower channel.  The screws have dual functions within the shower drain assembly:

1.)  A number of screws serve as leveling devices for the tiling frame to support the frame at its required height location.
These screws are located below the tiling frame and can be accessed through tool holes directly above the screw heads.

2.)  Other screws are located above the frame and secure the tiling frame down to the channel, once it is positioned
appropriately.

All of these screws are the same type and require a 1/8 [3] Allen wrench (provided) to adjust them.

To Adjust the Tiling Frame:

STEP 8:

  Measure the required finish floor height from the top surface of the waterproofing membrane to the top edge of

the tiling frame.

STEP 9:

  Loosen each #10-24 FHHSS that secures the tiling frame until the frame can move freely up and down.

STEP 10:

  With the tiling frame resting on the leveling screws underneath, use the 1/8 [3] Allen wrench provided and insert

into the access holes to adjust the height of the #10-24 leveling screws upwards as needed.  The leveling screws can be
adjusted at various elevations to raise the frame upward and to also help set the frame at a required pitch to meet the
finished floor surface.  

To prevent damage to the channel inserts, DO NOT over-tighten the leveling screws lower

than the preset screw height furnished.

WARNING - TO AVOID DAMAGE TO OR COMPROMISE OF
THE THREADED INSERT SEAL, DO NOT OVER-TIGHTEN
THE FRAME SECURING SCREWS AND LEVELING
SCREWS BEYOND A TORQUE OF 20 IN-LBS.

THE FRAME LEVELING SCREWS ARE PRESET AT THEIR
LOWEST HEIGHT AND CANNOT BE TORQUED ANY
LOWER DURING INSTALLATION.

STAINLESS STEEL

THREADED INSERTS

#10-24 x 

7

8

 FHHSS

LEVELING SCREWS

SHOWER DRAIN

CHANNEL

ACCESS HOLE TO

LEVELING SCREWS

FRAME SECURING

SCREWS

13

32

 [10] MIN.

FRAME ADJUSTMENT RANGE

29

32

 [23] MAX.

Содержание ZS880

Страница 1: ...near drain please pay close attention to the following guidelines and warnings Please handle all stainless steel material with caution The manufacturing process used in making this product can inadvertently produce sharp edges which may result in injury if handled or used improperly Please adhere to all torque specification requirements outlined within these instructions when tightening hardware d...

Страница 2: ...nce the anchor legs are placed at the necessary height retighten each 6 32 PHMS to secure the legs in place STEP 4 Attach the 2 51 no hub drain outlet to the 2 51 drain pipe before lagging the anchor legs down A shielded coupling shall be used to make this connection Ensure that the coupling clamps are tightened before lagging the anchor legs down to a base STEP 5 For convenience the anchor legs a...

Страница 3: ...are the same type and require a 1 8 3 Allen wrench provided to adjust them To Adjust the Tiling Frame STEP 8 Measure the required finish floor height from the top surface of the waterproofing membrane to the top edge of the tiling frame STEP 9 Loosen each 10 24 FHHSS that secures the tiling frame until the frame can move freely up and down STEP 10 With the tiling frame resting on the leveling scre...

Страница 4: ...crews will be obscure when viewing the top surface of the grate Note The in lay tile grate rests inside of the tiling frame and does not get secured to the frame To Secure the Grate STEP 14 Locate the two crossbars on the underside of the grate and note their locations STEP 15 Set the grate into the frame so that it sits flush and centered Viewing through the slots of the grate from the top side t...

Страница 5: ...2 Ph 905 405 8272 Fax 905 405 1292 www zurn com Rev Date 4 23 2018 C N No 139950 Form No FT1009 Page 5 of 6 Dimensional data inches and mm are subject to manufacturing tolerances and change without notice Typical Installation Drawing SUBFLOOR THINSET ADHESIVE ADJUSTABLE TILING EDGE FRAME WATERPROOFING MEMBRANE TILE THINSET ADJUSTABLE LEG TILE THINSET WATERPROOF MEMBRANE CONCRETE SUBFLOOR GROUT TIL...

Страница 6: ...44 Nashua Drive Mississauga Ontario L4V 1L2 Ph 905 405 8272 Fax 905 405 1292 www zurn com Rev Date 4 23 2018 C N No 139950 Form No FT1009 Page 6 of 6 Dimensional data inches and mm are subject to manufacturing tolerances and change without notice Typical Drain Placement in Bathroom Floor Construction Back of the Shower Location Multi Unit Shower Room Entrance Way Curb or Curbless ENTRANCE ENTRANCE...

Отзывы: