INSTALLATION INSTRUCTIONS FOR
ZN1201, ZF1201, Z1201-XH, AND Z1201-XB
WATER CLOSET SYSTEMS
Zurn Industries, LLC
|
Specification Drainage Operation
1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929
Rev.
B
In Canada |
Zurn Industries Limited
Date:
04/13/2018
3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292
C.N. No.
139851
www.zurn.com
Form #
C51
Page
1 of 5
1. Lay carrier fitting on floor, waste line barrel down.
See
Figure 1
.
2. Place faceplate gasket from trim kit on fitting. Align
the gasket holes with the tapped holes in the fitting.
See
Figure 2
.
3. Remove the faceplate/feet from trim kit box and align
the faceplate slots with the gasket and fitting holes.
Secure the (4) ø½ [13] bolts, from 66955-332-9
hardware bag, using a torque wrench (25-35 lb-ft of
torque).
- For ZF1201, see
Figure 3a
.
- For ZN1201 and Z1201-XH/XB, see
Figure 3b
.
4.
For ZN1201 and Z1201-XH/XB:
To adjust the rough-in height, loosen the feet bolts
(see
Figure 4a
) and set the desired height (adding
additional height for tiling where required). Secure
bolts using a torque wrench (25-35 lb-ft of torque).
Note:
For certain rough-in heights, the
bottom of the faceplate may need to be
removed along the defined cut lines.
See
Figure 4b
.
For ZF1201:
The rough-in height is pre-set and cannot be
adjusted.
Figure 3a
Figure 3b
Figure 1
Figure 2
Figure 4a
Figure 4b
ؽ [13]
ZF1201
ZN1201 &
Z1201-XH/XB
(4x)