background image

3

LTE Cellular Connection

If your gateway is configured for LTE cellular capability (Model  

ZGW-LORA-W1-LTE), it will have shipped to you with an active SIM  

card already installed.

Note: 

The ZGW-LORA-W1-LTE works only on the AT&T network, and 

connects automatically once the gateway is powered and in range of 

the AT&T network signal.

Cabling, Powering and Connecting  

Your Device

1.  Connect one end of the RJ45 Ethernet cable (supplied) to the 

gateway’s Ethernet port and plug the cable’s other end into the 

nearest wall port of the building’s Ethernet network.

2.  Connect the power supply to the power jack.
3.  Wait for status LED to go from ON to double flash every second, the 

LoRa LED to turn ON solid, and the cell LED (if LTE enabled) to flash 

once every 3 seconds. Should take around 1-2 minutes depending on 

location. Your gateway is now ready to transmit data from your Zurn 

connected product.

ITEM

DESCRIPTION

LEDS

Status

Blinks when operating system is fully loaded.

LoRa

LoRa service active LED displays ON when actively 

connected and OFF when not connected. 

Cell

Cellular models only.  

Lights when there is power to the radio.  

Blinks when the SIM is registered with the carrier.

WiFi

Reserved for future use. Always OFF.

Ethernet Link  
(Green)

Left LED on the Ethernet connector. Blinks when data is 

sent or received on the Ethernet link. Steady light when 

there is a valid Ethernet connection.

Ethernet Speed  
(Orange)

Right LED on the Ethernet connector.  

Lit when the Ethernet is linked at 100 Mbps.  

If not lit, the Ethernet is linked at 10 Mbps.