![ZURN Sundara Z5006.03 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/zurn/sundara-z5006-03/sundara-z5006-03_installation-maintenance-and-parts-manual_942504007.webp)
FV658 Rev. A 7/27/2018
Page 7
Retrofitting Hanger Bracket Installation
Recommended for retrofit:
• Measure the rough in dimensions on the wall. Top edge of the cutout marked must be 2” below the basin top back
edge.
• Cut the drywall to suitable size (90”x10”) and attach a minimum of 1/2” thick plywood to the wall stud and flush to the
drywall.
•
Drill eight ¾” holes in the plywood at the locations shown in the graphic to the top. Then, install the supplied toggle
anchors to wall and secure the hanger bracket(s) directly to the plywood with the supplied bolts.
• Install hanger bracket to wall per structural rough-in. (Note: An offset might be necessary on applications using tile to
get the basin and mounting brackets flush with wall and mating to bracket)
• The plywood should not be visible after basin and shroud installation.
• The bracket needs to be checked for level after installation.
1 [25]
312
[89]
4 [99]
312
[89]
1 [25]
312
[89]
4 [99]
312
[89]
17
15
16
Plywood
Wall Stud
Bolt supplied by
installer to attach
the plywood to
wall studs
Hanger Bracket
Hanger Bracket
Wall Stud
Drywall
1/2” Thick