LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the 

date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are 

notified in writing of such defect and the goods are returned to us prepaid at Atlanta, GA, with evidence that they have been properly 

maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages 

whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the 

defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the 

purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantabi

-

lity is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to 

a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists 

are approximate and are not guaranteed.

NOTE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.

NOTE: The information in this manual is subject to change at any time without notice. Installations may 

be performed at different times of construction by different individuals. For this reason, these instructions 

should be left on-site with the facility or maintenance manager.

Z5006.03

Installation, Maintenance, 

and Parts Manual

PATENT(S) PENDING

ZURN INDUSTRIES, LLC 

5900 Elwin Buchanan Drive, Sanford, NC U.S.A. 27330, Ph. 1-800-997-3876, Fax 919-775-3541

In Canada: 

ZURN INDUSTRIES LIMITED 

7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292

Rev. A 

Date: 7/27/2018 

C.N. No. SAN008319 

Prod. | Dwg. No. FV658

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

Содержание Sundara Z5006.03

Страница 1: ... warranty of merchantabi lity is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods All weights stated in our catalogs and lists are approximate and are not guaranteed NOTE READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT NOTE The in...

Страница 2: ...ndal Resistant Standard Paired Soap Dispenser Typical Specification Refer to soap dispenser manual for more details on specific model Power Supply AC 110 V DC 6V Soap Viscosity 100 3800 cps Operating Temperature 340 1310 F Typical Dispensed Volume 1 25 ml Important Safety Information Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances Do...

Страница 3: ...ter Supply Items 6 8 P Trap Assembly 3 9 Sensor Faucet 3 10 Soap Dispenser If Ordered 3 11 5 16 18 Screw for Mounting L Bracket to Basin 12 12 10 24 Screw for Shroud 2 13 Coarse Screw for Wall Bracket 2 14 Oversize 5 16 Washer 12 15 3 8 16 Hex Bolt with washer 33 16 3 8 Toggle Never Drop Anchor 39 17 3 8 Fender Washer 33 18 5 16 x 2 5 8 Clevis Pin 2 19 18 8 SS Hairpin Cotter 2 6 8 5 4 7 9 10 11 15...

Страница 4: ...chor next to each pivot point to prevent execessive flexing when shroud is in fully open position 3 1 4 84 34 863 29 1 2 752 28 3 4 733 14 3 4 378 1 1 2 36 3 1 4 80 4 102 6 152 15 381 90 2286 3 1 4 84 20 508 6 152 15 381 20 508 10 253 6 152 15 381 20 508 10 253 1 3 4 44 19 1 2 493 29 735 2 3 4 71 16 404 4 102 4 102 4 102 4 102 4 102 4 102 4 102 4 102 4 1 2 111 4 102 4 102 4 102 4 102 4 102 4 102 4...

Страница 5: ...asin on its top surface on a cushioned surface Use socket wrench to torque the screws approximately 4 5 complete turns bottom out approximately 5 ft lbs of torque Warning Do not overtighten the screws Avertissement ne pas trop serrer les vis 11 15 Faucet Installation For ease of installation lay basin on its back Refer to faucet installation guide for details ...

Страница 6: ...e of installation lay basin on its back Install the soap spout on right or left soap hole as applicable Refer to soap dispenser installation guide for details For ease of installation lay basin on its back Place grid draininto drainage opening Fasten washer and nut from underside of basin ...

Страница 7: ...ied toggle anchors to wall and secure the hanger bracket s directly to the plywood with the supplied bolts Install hanger bracket to wall per structural rough in Note An offset might be necessary on applications using tile to get the basin and mounting brackets flush with wall and mating to bracket The plywood should not be visible after basin and shroud installation The bracket needs to be checke...

Страница 8: ...d Warning Must be handled by at least 3 people Warning Ensure the basin back edge is completely supported in the wall bracket Avertissement s y prendre à trois minimum Avertissement s assurer que le bord arrière du bac est complètement soutenu par le support mural Mounting Bracket Bolt supplied by installer to attach the plywood to wall studs 16 15 17 Plywood Wall Stud ...

Страница 9: ...er to soap dispenser installation guide for details Installing with Carrier Option Warning Must be handled by at least 3 people Avertissement s y prendre à trois minimum Refer to Carrier Rough in Installation guide for details Optional Waste Line Sleeve WL Z1240 EZR Carrier System ...

Страница 10: ...ch P Trap to tailpiece Shroud Installation Step 1 Align wall bracket as shown and install coarse screw on each side Mark the slots in the wall bracket on the wall Note Anchors and bolts location can be flexible base on on site wall studs location Note A minimum of one anchor next to each pivot point is required to prevent excessive flexing when shroud is in fully open position 13 13 Pivot Point Pi...

Страница 11: ...rked Ensure that wall studs are not immediately behind the marked hole locations prior to drilling Install anchor toggle bolts into previously drilled holes in walls Step 3 Re install wall bracket with coarse screws in previous location Then fasten the wall bracket with 3 8 bolts through each holes and into the toggle bolts Step 2 16 15 ...

Страница 12: ...he shroud will likely need to be rotated upward slightly in order to install each pivot After one pivot is installed retain clevis pins with the included cotter pins Step 5 Rotate the shroud up to the basin until the threaded hole in the L bracket in visible through the slot in the shroud Then install the screw shown and repeat for the other side Step 4 18 19 12 12 ...

Страница 13: ...n wash the surfaces and rinse with water Avoid exposing solid surface basin with strong chemicals such as acetone based cleaners and solutions If surfaces are exposed to these chemicals quickly rinse the surface with water Repair Instructions Zurn recommends that damages should be repaired by certified solid surface fabricator or repair agents Blemishes to the basin surface such as scratches burn ...