FV617 Rev. - 4/17/2017
Page 4
Z6957-SD
Spout Installation
1.
Remove the escutcheon from the dispenser
assembly by unscrewing counter-clockwise. Correctly
orient the dispenser and mark the holes.
2.
Remove the two retention screws and remover the
body from the base. Drill 3/16" holes on the marks
and insert anchors. Attach the base to the wall using
the supplied screws
4.
Reinstall the escutcheon by threading it clockwise
onto the base.
3.
Feed the soap tube and sensor connector through the
wall and reattach the body to the base by tightening
the retention screws.
Note:
It is recommended to horizontally offset the soap dispenser spout with the faucet 4 - 6” and to install vertically 6-10" above
the sink drain at the same height as the faucet. To comply with ADA standards, the center-point of the soap dispenser
spout must be less than 50" from finished floor.
Installation Overview
The dispenser is mounted directly to the wall above
the basin. The control box is mounted below the
basin and the soap tube and sensor connector are
run through the wall behind the basin and back out
the front of the wall to the control box below the
basin.