background image

18

PHIX

®

 Cartridge System

Owners Manual

6)  General Terms and Conditions

Price and Terms of Payment

Terms are net, payable 30 days from date of invoice. All pricing in U.S. currency. The Buyer shall pay 

all sales, consumers, or other applicable taxes. A 1-1/2% monthly (18% annual) service charge will be 

added to the outstanding balance of all past due invoices.
Minimum invoice $100.00. Zurn Industries, LLC ("Zurn") reserves the right to apply a minimum order 

charge in order to meet the $100.00 minimum invoice requirement. All orders are subject to credit 

approval by the Zurn Credit Department prior to the acceptance of an order. Orders may be refused, 

delivery may be withheld, or shipment stopped in transit without any liability on Zurn’s part at Zurn’s 

sole discretion based upon Buyer’s credit worthiness as determined by Zurn.

Freight

Zurn is pleased to provide an industry-leading $3,500 combined freight rate. Please see below for 

specific policy details.
All sales are F.O.B. seller’s location. Zurn will allow full freight allowance when any of the following 

conditions are met:
1)  any combination of Specification Drainage, Light Commercial, Commercial Brass or Wilkins orders 

of $3,500 or more;
2)  Linear Drainage and Chemical Drainage orders of $5,000 or more; 3) any Combination of 

Specification Drainage, Light Commercial, Commercial Brass, Wilkins, Linear Drainage and Chemical 

Drainage orders of $5,000 or more; 4) Zurn One Systems orders of $7,500 or more; 5) fixture only 

orders totaling $10,000 or more. This full freight allowance applies when the shipment is within the 

continental United States and has a single destination of a buyer’s standard address or job location. 

Routing of shipment shall be determined at the sole direction of Zurn . Shipping dates are estimates 

and time of delivery shall not be of the essence of this sale contract. Under no circumstances will the 

Seller have any responsibility on account of any delays in manufacture, transportation, or otherwise. 

Terms of Export Shipment on application.
NOTE: Any product dimension larger than 92" or any single item weighing more than 3,500 lbs., shall 

be defined as an oversized and/or overweight product and Zurn’s standard FFA terms may not apply. 

Please contact our customer service department for guidance on potential additional shipping charges.
These charges and restrictions apply in addition to Zurn standard terms and conditions for sale unless 

otherwise agreed upon by the parties.

Limited Warranty

Zurn goods sold hereunder are warranted to be free from defects in material and factory workmanship 

for the period of time from the date of purchase: AquaVantage

®

 Flush Valves, AquaFlush

®

 Flush 

Valves, Commercial Fixtures, Faucets, Showers, and Tubular Brass three years; Chemical Drainage, 

Linear Drainage, Light Commercial, Specification Drainage, Zurn Wilkins, and Flush Valve and Tubular 

Brass decorative finishes one year; PHIX cartridge ten years. Where permitted by law, THE IMPLIED 

WARRANTY OF MERCHANTABILITY IS LIMITED TO THE ABOVE IDENTIFIED PERIOD OF TIME AND 

SHALL BE
LIMITED SOLELY TO THE REPLACEMENT OF THE DEFECTIVE GOODS. A damaged/broken test cock 

or ball valve is not considered defective. Please contact Zurn Customer Care for assistance.
Zurn will replace goods at no cost that prove defective provided Zurn is notified in writing of such 

defect and the goods are returned prepaid at the specified Zurn location with evidence that they 

have been properly maintained and used in accordance with instructions. ZURN SHALL NOT BE 

RESPONSIBLE FOR ANY LABOR CHARGES OR ANY LOSS, INJURY, OR DAMAGES WHATSOEVER, 

INCLUDING, BUT NOT LIMITED TO, INCIDENTAL OR CONSEQUENTIAL
DAMAGES. The sole and exclusive remedy shall be limited to the replacement of the defective goods. 

Before installation and use, the purchaser shall determine the suitability of the product for his intended 

use and the purchaser assumes all risk and liability whatever in the connection therewith. All weights 

stated in Zurn catalogs and lists are approximate and are not guaranteed.

Содержание PHIX

Страница 1: ...PHIX Owners Manual Acid Neutralization Systems ...

Страница 2: ...a point source acidic wastewater treatment solution complying with local plumbing codes throughout North America Your engineered system protects your building s plumbing piping and the local sanitary sewer infrastructure from corrosive acids Now you have a safe easy and worry free neutralization solution treating low pH where it starts at the sink ...

Страница 3: ...d Cartridge Body 6 2 Step by Step Installation Procedures 8 A Remove Drain 8 B Add PHIX Media to the PHIX Cartridge System 8 C Connect the PHIX Cartridge System 9 D Connect Plastic Waste Pipe 9 E Install Support Bracket 10 F Initial Startup Procedure 10 3 Maintenance of the PHIX Cartridge 10 3 1 Maintenance Inspection 10 3 2 Solids Removal 11 3 3 Media Replacement 13 4 PHIX Cartridge System Replac...

Страница 4: ...tridge fits directly underneath the sink removing the need for a collection tank to treat and store acidic wastewater prior to discharge into the sewer system 1 2 1 PHIX Media and Performance The PHIX Cartridge uses PHIX Media a mix of solid alkali non resin materials to neutralize acidic wastewater It is used throughout the neutralization process and is replaced as required It permits better cont...

Страница 5: ...se immediate damage to the environment Highly corrosive causing severe physical injury to plant and animal life coming in contact with it Ease of Handling No special handling or equipment required Expensive solids and handling equipment is required Requires elaborate safety equipment and rigorous time consuming safety procedures Equipment Costs No initial capital cost Initial capital cost required...

Страница 6: ...he top manifold NOTE Any modifications to the unit will alter the ability of the System to effectively treat wastewater 1 5 1 Top Manifold The Top manifold of the cartridge houses the unit s three main connections Figure 1 3 A Threads to the sink drain B Connection to the drain pipe and C Threads into the Body of the PHIX Cartridge 1 5 2 Internal Skeleton and Cartridge Body The Internal Skeleton d...

Страница 7: ...omponents TOP MANIFOLD INTERNAL SKELETON BODY BRASS NUT AND COMPRESSION RING MANIFOLD O RING TOP FILTER PLATE FILTER BOTTOM FILTER PLATE CENTER COLUMN MEDIA FILTER PLATE CARTRIDGE BODY TREATMENT CHAMBER Figure 1 3 Top Manifold A B C Figure 1 4 Cartridge Cross Section and Flow Pattern ...

Страница 8: ...e trap place a plastic bucket under the drain trap to catch any standing water B Add PHIX Media to the PHIX Cartridge System The PHIX Cartridge System is shipped with two packs of media for initial charge and a refill To ensure that acidic wastewater is properly neutralized the cartridge must be loaded with the initial charge of media before it is installed To add PHIX Media to the PHIX Cartridge ...

Страница 9: ...l Figure 2 2 Connection between the PHIX Cartridge and Sink D Connect Plastic Waste Pipe Connect a pipe between the outlet of the cartridge and the stub out drain fitting Options for connecting the outlet pipe are illustrated below All piping from the PHIX Cartridge System must meet the local plumbing codes Figure 2 3b Unions Bonded with Adhesive Option Use Construction Adhesive designed for low s...

Страница 10: ...est to verify there are no leaks Flow test Run water from tap into sink and visually inspect threaded connections 1 If a leak is detected tighten the threaded connections until the leak has stopped 2 Once the leak test is passed the PHIX Cartridge System is ready for operation 3 Maintenance of the PHIX Cartridge The maintenance of the PHIX Cartridge System is critical to prevent disruption in the ...

Страница 11: ...to the bucket Figure 3 4 Once the liquid and PHIX media is removed pull the center column out Figure 3 5 With all the components removed from the body rinse out the bottom of the cartridge to remove any solids Place the center column with the media filter plate in place back into the cartridge body Pour the media back into the cartridge or if the media is spent replace the media with new PHIX Medi...

Страница 12: ...IX Cartridge System Owners Manual Figure 3 2 Remove Cartridge Figure 3 3 Remove Filter Plates and Filter Figure 3 4 Dispose of spent PHIX Media Figure 3 5 Remove Center Column Clean Cartridge and Re assemble ...

Страница 13: ...posal 5 Remove the top filter plate the filter and bottom filter plate from the cartridge body 6 Turn the cartridge at an angle and dispose the spent PHIX media into a trash bin No special handling of used PHIX media is required 7 Once the PHIX media is removed pull the center column out 8 With all the components removed from the cartridge body rinse out the bottom of the cartridge to remove any s...

Страница 14: ...stomer Care Representative for more information at 1 855 ONE ZURN or visit www Zurn com REPLACEMENT PARTS PHIX Media O ring Filter Top or Bottom Filter Plate Media Filter Plate TOP MANIFOLD INTERNAL SKELETON BODY BRASS NUT AND COMPRESSION RING MANIFOLD O RING TOP FILTER PLATE FILTER BOTTOM FILTER PLATE CENTER COLUMN MEDIA FILTER PLATE CARTRIDGE BODY TREATMENT CHAMBER ...

Страница 15: ...PHIX Cartridge System Owners Manual 15 1 1 1 1 1 3 5 PHIX Cartridge System Technical Drawing and Installation Configuration ...

Страница 16: ...artridge System Owners Manual A A SECTION A A PHIX MEDIA TOP BOWL SUMP CUP AIR FILTER CUT OUT O RING SEAL BOTTOM FILTER PLATE BOTTOM PLATE CENTER COLUMN COMPRESSION FITTING FERRULE TAIL PIPE NUT TOP FILTER PLATE ...

Страница 17: ...m Owners Manual 17 UNDER THE SINK APPLICATION i e HOSPITAL LABORATORY HIGH SCHOOL PHARMACEUTICAL UNIVERSITY LAB CARTRIDGES REGULAR PVC PIPING A B LIGHT APPLICATION TO CITY SEWER TO CITY SEWER PHIX Cartridge Configurations ...

Страница 18: ...unt of any delays in manufacture transportation or otherwise Terms of Export Shipment on application NOTE Any product dimension larger than 92 or any single item weighing more than 3 500 lbs shall be defined as an oversized and or overweight product and Zurn s standard FFA terms may not apply Please contact our customer service department for guidance on potential additional shipping charges These...

Страница 19: ...tended to illustrate the products and potential options for the use of these products Under no circumstances are they to be construed as recommended installation procedures Consult local codes and project specifications for proper installation instructions Shortage Damage Claims Notification of material shortages or incorrect filling of orders must be made to Zurn within 10 days of receipt No clai...

Страница 20: ...0 22 Rev 9 15 In Canada ZURN INDUSTRIES LIMITED 3544 Nashua Drive Mississauga Ontario L4V 1L2 905 405 8272 ZURN INDUSTRIES LLC Specification Drainage Operation 1801 Pittsburgh Avenue Erie PA 16502 855 663 9876 ...

Отзывы: