8

5.) 

Determine the length of the vacuum breaker tube 

(F) 

required  to  join  the  flush  valve  and  fixture  spud.  Cut  the 

vacuum breaker tube, if required, to this length. Assemble 

the vacuum breaker tube assembly and spud nut assembly 

to the flush valve and fixture spud.

5

F

8.) 

Determine all flush valve connections are tight and 

proceed to open control stop.

D

H

G

Vacuum

Breaker

Tube Nut

Spud Nut

Slip Gasket

Rubber

Gasket

Spud

Escutcheon

6.) 

Hand tighten spud nut 

(G)

 to the fixture and vacuum breaker 

tube nut 

(H)

 to flush valve. Adjust the valve assembly for 

plumb.  Tighten fixture spud nut 

(G)

, vacuum breaker tube 

nut 

(H)

 and lock nut 

(D)

 (fig. 5) with a wrench.

6

7

7.) 

Attach the appropriate handle/actuator to the valve body.

ZER

ZEMS-IS

ZEMS

Z

Содержание Metroflush Z6200 series

Страница 1: ...ment of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is...

Страница 2: ...ly piping to remove dirt metal chips etc from system A Before the valve is installed open each stop fully for a brief time and catch the water in a two gallon or larger bucket For multiple installations start with the stop valve closest to the water supply and work toward the most remote valve B Due to the small passages and orifices it is not possible to flush the piping through the low volume va...

Страница 3: ...d fixture spud 5 F 8 Determine all flush valve connections are tight and proceed to open control stop D H G Vacuum Breaker Tube Nut Spud Nut Slip Gasket Rubber Gasket Spud Escutcheon 6 Hand tighten spud nut G to the fixture and vacuum breaker tube nut H to flush valve Adjust the valve assembly for plumb Tighten fixture spud nut G vacuum breaker tube nut H and lock nut D fig 5 with a wrench 6 7 7 A...

Страница 4: ...utside Cover Item 22 P6200 LL Outside Cover O Ring Item 23 P6200 L12 3 5 gpf Closet Repair Kit Item 24 P6200 EC 1 5 gpf Urinal Repair Kit Item 24 P6200 EU 1 6 gpf Low Consumption Closet Kit Item 24 P6200 EC WS1 1 0 gpf Low Consumption Urinal Kit Item 24 P6200 EU WS1 1 28 gpf High Efficiency Closet Kit Item 24 P6200 EC HET 0 5 gpf High Efficiency Urinal Kit Item 24 P6200 EU EWS Main Seat Item 25 P6...

Страница 5: ...ot shutting off 1 Trip mechanism not seating properly due to foreign material between trip mechanism and seat 1 Disassemble parts and rinse thoroughly 2 By pass orifice is plugged or partially plugged 2 Examine by pass orifice and clean if necessary being certain not to enlarge orifice opening 3 Line pressure is not adequate to force trip mechanism to seal 3 Pressure is inadequate or has dropped b...

Отзывы: