METERING FAUCET TROUBLE SHOOTING GUIDE
Problem
Cause
Solution
No water dispensing
from faucet.
Supply stops not open.
Open supply stops.
Spray outlet (item 6) contaminated.
Remove spray outlet (item 6) to clean and/or replace.
Filter assembly (item 4) contaminated.
Shut off water supply. Remove filter assembly to clean and/
or replace. Filter located internally within faucet body under
metering cartridge.
Faucet is shutting
off too quickly
Timing nut (item 2E) requires adjustment.
Remove handle (item 1) using 3/32” Allen wrench. Rotate
timing nut (item 2E) down (CW) to lengthen handle stroke
and increase cycle time.
Metering cartridge (item #3) is damaged.
Replace metering cartridge (item 3) G61754 per Installation
and Maintenance guide, page 2
Faucet is running
too long or will not
shut off
Timing nut (item 2E) requires
adjustment.
Remove handle (item 1) using 3/32” Allen wrench. Rotate
timing nut (item 2E) up (CCW) to shorten handle stroke and
decrease cycle time.
Metering cartridge (item 3) is overly contaminated or
damaged.
Replace metering cartridge (item 3) G61754 per Installation
and Maintenance guide, page 2
Spray outlet (item 6) is not installed or incorrect spray
outlet (item 6) installed.
Install 1.0 GPM or 0.5 GPM spray outlet (item 6). Facuet
may not shut off with flow rate > 1.0 GPM.
Handle nut (item 2) is not adequately tightened
Tighten handle nut (item 2) using 1-1/8” hex 6 point socket
to create seal and seat metering cartridge. Do not over
tighten.