MAINTENANCE

1.  YOUR ZURN AQUASPEC FAUCET HAS A HIGHLY POLISHED NICKEL CHROME PLATED FINISH.  CLEAN WITH SOAP  

AND WATER OR A MILD CLEANER WHICH IS SAFE FOR CHROME PLATING.  DO NOT USE ACIDS OR TOILET BOWL 

CLEANER AS THEY WILL DAMAGE THE FINISH.

2.  METERING CARTRIDGE (#3) REMOVAL AND REPLACEMENT (SEE SERVICE VIDEO AT WWW.ZURN.COM/OPERATIONS/ 

 AQUASPEC/PAGES/SERVICEVIDEOMENU.ASP)

2.1.  REMOVE COLORED INDEX BUTTON (#1C) FROM HANDLE (#1A)
2.2.  LOOSEN SET SCREW (#1B) IN HANDLE WITH 3/32” ALLEN WRENCH
2.3.  PULL UP ON HANDLE TO REMOVE FROM STEM (#2C) OF HANDLE NUT ASSEMBLY (#2)
2.4.  REMOVE HANDLE NUT ASSEMBLY (#2) USING 1-1/8” HEX 6-POINT SOCKET
2.5.  REMOVE METERING CARTRIDGE (#3) BY LIFTING OUT OF FAUCET BODY (#4). IT MAY BE NECESSARY TO 

OPEN THE SUPPLY STOP SLIGHTLY TO ALLOW WATER PRESSURE TO PUSH THE METERING CARTRIDGE UP-

WARD.

2.6  INSPECT METERING CARTRIDGE (#3) FOR WORN PARTS, DAMAGED PARTS AND ANY CONTAMINATION 

THAT MAY BE PREVENTING THE METERING CARTRIDGE FROM MOVING FREELY OR SEATING. OTHER THAN      

CLEANING ANY TRAPPED DEBRIS, THERE ARE NO SERVICEABLE PARTS IN THE METERING CARTRIDGE. CON-

TAMINATED OR DAMAGED METERING CARTRIDGE ASSEMBLIES SHOULD BE REPLACED.

2.7  REVERSE STEPS 2.1 THROUGH 2.5 FOR RE-ASSEMBLY. METERING CARTRIDGE (#3) WILL SIT SLIGHTLY ABOVE 

BODY (#4) PRIOR TO MOUNTING OF HANDLE NUT ASSEMBLY.  TIGHTEN CAP (#2F) WITH 1-1/8” HEX 6-POINT 

SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS 

RUNNING. HOLD DOWN HANDLE (#1A) WHILE TIGHTENING SET SCREW (#1B) TO ENSURE PROPER SEATING

ADJUSTING THE CYCLE TIME ON ZURN METERING FAUCET

(SEE SERVICE VIDEO AT WWW.ZURN.COM/OPERATIONS/AQUASPEC/PAGES/SERVICEVIDEOMENU.ASP)

1.  METERING FAUCETS ARE FACTORY PRESET FOR A 10  TO 15 SEC. CYCLE AT 80 PSI.

2.  ACTUATE FAUCET 3 TO 5 TIMES TO REMOVE ANY TRAPPED AIR IN THE SUPPLY LINE OR FAUCET

3.  REMOVE HANDLE (#1) PER INSTRUCTIONS IN MAINTENANCE SECTION 2.1 THROUGH 2.3 TO EXPOSE ADJUSTMENT  

  NUT (#2E)

4.  INCREASE CYCLE TIME BY TIGHTENING ADJUSTMENT NUT (#2E) 1/2 TURN CLOCKWISE. DECREASE CYCLE TIME BY  

  LOOSENING ADJUSTMENT NUT 1/2 TURN COUNTERCLOCKWISE. CHECK FOR DESIRED CYCLE TIME BY ACTUATING  
 FAUCET 

WITH HANDLE (#1) IN PLACE ON STEM (#2C)

 Installation Instructions are revised frequently.  

 Please access website for the latest revision.

*

REPLACEMENT PARTS

HANDLE 

NUT 

ASSEMBLY 

  G60561

METERING CARTRIDGE ASSEMBLY 

G61754

HANDLE 

ASSEMBLY 

  G60522

Содержание AQUASPEC Z80300 Series

Страница 1: ...ERATOR ADAPTOR 5 AND AERATOR 6 INTO FAUCET AND HAND TIGHTEN 5 METERING CARTRIDGE IS FACTORY PRESET FOR A 10 TO 15 SECOND CYCLE AT 80 PSI IF ADJUSTMENT IS NECESSARY SEE ADJUSTING THE CYCLE TIME SECTION PAGE 2 IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT FOREIGN MATTER AND DEBRIS FROM CLOGGING AND OR DAMAGING INTERNAL COMPONENTS FLOW 0 25 GPC MAXIMUM PRES...

Страница 2: ...E METERING CARTRIDGE FROM MOVING FREELY OR SEATING OTHER THAN CLEANING ANY TRAPPED DEBRIS THERE ARE NO SERVICEABLE PARTS IN THE METERING CARTRIDGE CON TAMINATED OR DAMAGED METERING CARTRIDGE ASSEMBLIES SHOULD BE REPLACED 2 7 REVERSE STEPS 2 1 THROUGH 2 5 FOR RE ASSEMBLY METERING CARTRIDGE 3 WILL SIT SLIGHTLY ABOVE BODY 4 PRIOR TO MOUNTING OF HANDLE NUT ASSEMBLY TIGHTEN CAP 2F WITH 1 1 8 HEX 6 POIN...

Страница 3: ...1B 62705001 Set Screw 1 1C G60558 Metering Index Buttons H C T 1 60460001 Hot Index 1 60460002 Cold Index 1 60460003 Tempered Index 1 2 G60561 Handle Nut Assembly 1 2A 60465001 E Ring 1 2B 60464001 Spring Seat 1 2C 60451003 Stem 1 2D 60447001 Spring 1 2E 60446001 Adjustment Nut 1 2F 60452001 Cap 1 2G 60456001 Stem Housing 1 2H 62499107 O Ring 1 2I 60458001 O Ring Retainer 1 3 G61754 Valve Sleeve P...

Страница 4: ...nt Remove handle item 1 using 3 32 Allen wrench Rotate timing nut item 2E down CW to lengthen handle stroke and increase cycle time Metering cartridge item 3 is damaged Replace metering cartridge item 3 G61754 per Installation and Maintenance guide page 2 Faucet is running too long or will not shut off Timing nut item 2E requires adjustment Remove handle item 1 using 3 32 Allen wrench Rotate timin...

Отзывы: