background image

PAGE 1 OF 4

ZURN INDUSTRIES, LLC 

5900 Elwin Buchanan Drive, Sanford, NC U.S.A. 27330, Ph. 1-800-997-3876, Fax 919-775-3541

In Canada: 

ZURN INDUSTRIES LIMITED 

7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292

Rev. J 

Date: 8/7/2018 

C.N. No. SAN008347  

Prod. | Dwg. No. CF1025

AQUASPEC FAUCETS

MODEL - Z80300 SERIES

WALL MOUNTED SINGLE METERING FAUCET

TECHNICAL INFORMATION

®

INSTALLATION INSTRUCTIONS

1.  THE WATER SUPPLY LINE MUST BE THOROUGHLY FLUSHED BEFORE FAUCET INSTALLATION.

2.  REMOVE FAUCET BODY FROM CARTON AND MOUNT TO 1/2” NPT FITTING.

3.  TURN SUPPLY WATER ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS

4.  INSTALL  AERATOR ADAPTOR (#5) AND AERATOR (#6) INTO FAUCET AND HAND TIGHTEN. 

5.  METERING CARTRIDGE IS FACTORY PRESET FOR A 10 TO 15 SECOND CYCLE AT 80 PSI, IF ADJUSTMENT IS 

 

NECESSARY, SEE “ADJUSTING THE CYCLE TIME” SECTION (PAGE 2).

*

IMPORTANT 

THE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT 

FOREIGN MATTER AND DEBRIS FROM CLOGGING AND/OR DAMAGING INTERNAL COMPONENTS

FLOW:

  0.25 GPC MAXIMUM; PRESET AT FACTORY TO 10 TO 15 SECONDS @ 80 PSI ADJUSTABLE

MAXIMUM PRESSURE:

  80 PSI

MAXIMUM TEMPERATURE:

  140

O

 

F

F

OPERATION - MINIMUM HAND PRESSURE TO START 5 POUND-FORCE, MAXIMUM PRESSURE 80 POUND FORCE.

CARTRIDGE STYLE - ZURN METERING CARTRIDGE

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

Содержание AQUASPEC Z80300 Series

Страница 1: ...ERATOR ADAPTOR 5 AND AERATOR 6 INTO FAUCET AND HAND TIGHTEN 5 METERING CARTRIDGE IS FACTORY PRESET FOR A 10 TO 15 SECOND CYCLE AT 80 PSI IF ADJUSTMENT IS NECESSARY SEE ADJUSTING THE CYCLE TIME SECTION PAGE 2 IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT FOREIGN MATTER AND DEBRIS FROM CLOGGING AND OR DAMAGING INTERNAL COMPONENTS FLOW 0 25 GPC MAXIMUM PRES...

Страница 2: ...E METERING CARTRIDGE FROM MOVING FREELY OR SEATING OTHER THAN CLEANING ANY TRAPPED DEBRIS THERE ARE NO SERVICEABLE PARTS IN THE METERING CARTRIDGE CON TAMINATED OR DAMAGED METERING CARTRIDGE ASSEMBLIES SHOULD BE REPLACED 2 7 REVERSE STEPS 2 1 THROUGH 2 5 FOR RE ASSEMBLY METERING CARTRIDGE 3 WILL SIT SLIGHTLY ABOVE BODY 4 PRIOR TO MOUNTING OF HANDLE NUT ASSEMBLY TIGHTEN CAP 2F WITH 1 1 8 HEX 6 POIN...

Страница 3: ...1B 62705001 Set Screw 1 1C G60558 Metering Index Buttons H C T 1 60460001 Hot Index 1 60460002 Cold Index 1 60460003 Tempered Index 1 2 G60561 Handle Nut Assembly 1 2A 60465001 E Ring 1 2B 60464001 Spring Seat 1 2C 60451003 Stem 1 2D 60447001 Spring 1 2E 60446001 Adjustment Nut 1 2F 60452001 Cap 1 2G 60456001 Stem Housing 1 2H 62499107 O Ring 1 2I 60458001 O Ring Retainer 1 3 G61754 Valve Sleeve P...

Страница 4: ...nt Remove handle item 1 using 3 32 Allen wrench Rotate timing nut item 2E down CW to lengthen handle stroke and increase cycle time Metering cartridge item 3 is damaged Replace metering cartridge item 3 G61754 per Installation and Maintenance guide page 2 Faucet is running too long or will not shut off Timing nut item 2E requires adjustment Remove handle item 1 using 3 32 Allen wrench Rotate timin...

Отзывы: