FV541 Rev. T 7/18/2018
Page 8
STEP 6.1
Remove vandal-resistant cover with allen wrench from control
stop (if present) and turn control stop clockwise to turn off the
water supply.
STEP 6.2
Press and hold the manual override button for 3 seconds to
release any residual pressure.
Figure 14
Figure 15
STEP 6.3 (For Hardwired Only)
Loosen set screw in wall escutcheon and slide escutcheon
against the sensor cap
Figure 16
STEP 6.4
Use a 5/64” allen wrench to remove the two cap screws from
the sensor cap and remove the sensor cap. See Figure 17.
Disconnect black solenoid plug.
Figure 17
Solenoid
connecting
wire
Metal Sensor Cap Retrofit Installation Instructions
STEP 6.5 (For Hardwired Only)
Disconnect the red sensor plug and loosen the wire supply tube.
Remove both the wire supply tube and escutcheon. Keep for
metal sensor cap installation.
STEP 6.6
Remove the 4 sockets screws shown in Figure 18 using a M3
allen wrench and discard the screws
Figure 18
Wall
Escutcheon
Wire Supply Tube
Right-hand Orientation
Left-hand Orientation
Remove
Remove
Remove
Remove