![Zte ZXSDR BS8800 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/zte/zxsdr-bs8800/zxsdr-bs8800_technical-manual_940275026.webp)
ZXSDR BS8800 Technical Manual
F
IGURE
13 -48V P
OWER
D
ISTRIBUTION
1. RF subrack
2. -48V power distribution subrack
3. Fan subrack
4. Baseband subrack 1
5. Baseband subrack 2
+24V Power
Distribution
With the adoption of +24V DC power supply, the +24V power dis-
tribution subrack implements overall equipment power distribu-
tion. After being led into the cabinet, primary power is distributed
to the RF subrack (composed of multiple
RSU
s) and fan subrack.
The PSU subrack co24V DC into —48V DC to provide for
BBU. The PDM provides 8 circuit breakers to control power-on and
power-off of the BBU, fan subrack and every RSU.
Figure 14
illus24V power distribution principle.
20
Confidential and Proprietary Information of ZTE CORPORATION