ZXG10 iBSC Hardware Installation Guide
you can not meet the position requirements about two cutting points, you shall re-cut
the feeder sheath to meet the two above requirements, in the unit of mm.
Figure 7-8 Cutting Position of Outer Conductor for 1/4" Feeder
The methods of cutting outer conductor is shown in
.
Figure 7-9 Cutting Method of Outer Conductor for 1/4" Feeder
3.
Slightly rasp the inner conductor by using a file, enable it reach 0.3 x 45 degrees. That
is, make the top flat and enable the edge form a slope. Also, the angle between the
slope and inner conductor is 45 degrees. The length of inner conductor corresponding
to the slope is about 0.3 mm, as shown in
. Note that no any burr occurs
on the processed inner conductor, otherwise it may impact the quality of received GPS
signal.
7-10
SJ-20110531095035-004|2011-10-28 (R2.0)