Startup/Shutdown procedure
6.1
Startup steps
1)
Startup steps: Assure address dip switches are set correctly
2)
Turn ON the external circuit breaker
3)
Push Power button for 3 seconds
6.2
Shutdown steps
1)
Push Power button for 3 seconds
2)
Turn off external braker
6.3
SLEEP AND WAKE UP
When any of the following conditions is met, the battery enters the low-power mode:
•
Undervoltage protection is not released within 90 seconds.
•
The reset button is pressed for 3 seconds and then released.
•
The lowest cell voltage is lower than the sleep voltage, and the duration of such state
reaches the sleep delay time (while meeting the requirements of no communication, no
protection, no equilibrium, and no current).
•
Standby mode lasts for more than 24 hours (no communication, no charge or
discharge,, minimum cell voltage is less than 3.2 V).
•
Forced shutdown from the EMS Tools level.
•
NOTE:
WAKE UP
When the system is in the low-power mode, and any of the following conditions is met, the
system will exit the low-power mode and enter the normal operation mode:
•
A charger is connected and the output voltage of the charger is greater than 51.2 V.
If there are other batteries in the output state in parallel application scenario, the
current battery cannot be set to sleep through the reset button, because it will be
charged and awakened by other batteries with normal output.