background image

All rights reserved.

Specifications are subject to change without notice.

User Manual

Содержание ZT102

Страница 1: ...All rights reserved Specifications are subject to change without notice User Manual...

Страница 2: ...purchase This warranty does not cover fuses disposable batteries damage from misuse accident neglect alteration contamination or abnormal conditions of operation or handling including failures caused...

Страница 3: ...3 Function Buttons 5 Rotary Switch 7 Input Terminals 9 Measurements Instruction 10 Measure AC DC Voltage 10 Measure AC DC Current 10 Measure Resistance 11 Test for Continuity 12 Test Diodes 12 Measure...

Страница 4: ...nce 17 Clean the Product 17 Replace the Batteries 17 Replace the Fuses 18 Specifications 19 General Specifications 19 Mechanical Specifications 19 Environmental Specifications 19 Electrical Specificat...

Страница 5: ...ety information before you use the product Please use the product only as specified or the protection supplied by the product can be compromised Examine the case before you use the product Look for cr...

Страница 6: ...changing the mode When the voltage to be measured exceeds 36V DC or 25V AC the operator shall be careful enough to avoid electric shock Misuse of mode or range can lead to hazards be cautious will be...

Страница 7: ...3 LCD Display Continuity test Temperature test Fahrenheit or Celsius Diode test Duty cycle test Display freezes present reading Resistance test Ohm Instrument Overview...

Страница 8: ...ange The user selects the range Auto range The product selects the range with the best resolution The product measures both sinusoidal and nonsinusoidal ac waveforms accurately Low battery Replace bat...

Страница 9: ...ge mode each push increases the range when the highest range is reached the next push will lead to the lowest range To exit the manual range mode turn the rotary switch Push for more than 2 seconds to...

Страница 10: ...g including 1 DC V AC V Frequency Duty Cycle 2 DC mV AC mV Temperature 3 Resistance Continuity Diode Capacitance 4 Frequency Duty Cycle 5 DC A AC A 6 DC A AC A 7 NCV Push for more than 2 seconds to ho...

Страница 11: ...1 minute before auto power off To restart the product from auto power off press the SEL HOLD button or turn the rotary switch back to the OFF position and then to a needed position To disable the Aut...

Страница 12: ...DC voltage 99 99mV AC voltage 99 99mV Celsius 20 1000 Fahrenheit 4 1832 Ohms 99 99M Continuity Beeper turns on at 50 Diode test Displays above 3V Farads 9 999mF Frequency with low voltage Duty Cycle...

Страница 13: ...ent measurements to 9 999A COM Common return terminal for all measurements V Hz Input terminal for the measurements of 1 AC DC voltage 2 Resistance 3 Capacitance 4 Frequency 5 Temperature 6 Continuity...

Страница 14: ...correct test points of the circuit to measure the voltage 5 Read the measured voltage on the display Measure AC DC Current 1 Connect the black test lead to the COM Terminal and the red lead to the V...

Страница 15: ...he test lead to the V Hz Terminal 2 Turn the rotary switch to and the display will show 3 Touch the probes to the desired test points of the circuit to measure the resistance 4 Read the measured resis...

Страница 16: ...bes to the desired test points of the circuit 4 The built in beeper will beep when the resistance is lower than 50 which indicates a short circuit Test Diodes 1 Connect the black test lead to the COM...

Страница 17: ...lay 5 If the polarity of the test leads is reversed with diode polarity or the diode is broken the display reading shows Measure Capacitance 1 Connect the black test lead to the COM Terminal and the r...

Страница 18: ...lead to the COM Terminal and the red lead to the V Hz Terminal 2 Turn the rotary switch to applies to low frequency with high voltage press SEL twice to toggle to the Frequency Mode or turn the rotar...

Страница 19: ...L three times to toggle to the Duty Cycle Mode or turn the rotary switch to applies to high frequency with low voltage press SEL once to toggle to the Duty Cycle Mode 3 Touch the probes to the desired...

Страница 20: ...probes to the desired test points 4 Read the measured temperature on the display Test NCV 1 Turn the rotary switch to 2 Hold the product and move it around the built in beeper will beep when the inne...

Страница 21: ...e instructions Clean the Product Wipe the product with a damp cloth and mild detergent Do not use abrasives or solvents Dirt or moisture in the terminals can affect readings Remove the input signals b...

Страница 22: ...es When a fuse is blown or do not work properly it shall be replaced as below 1 Remove the test leads and turn off the product before replacing the fuse 2 Loosen the four screws on the back cover and...

Страница 23: ...Rate 3 Times Second Ture RMS Data Hold Backlight Low Battery Indication Auto Power Off Mechanical Specifications Dimension 130 65 32mm Weight 114g Battery Type 1 5V AAA Battery 2 Warranty One year En...

Страница 24: ...on Accuracy DC Voltage V 999 9mV 0 1mV 0 5 3 9 999V 0 001V 99 99V 0 01V 999 9V 0 1V DC Voltage mV 9 999mV 0 001mV 99 99mV 0 01mV AC Voltage V 999 9mV 0 1mV 1 0 3 9 999V 0 001V 99 99V 0 01V 750 0V 0 1V...

Страница 25: ...9A 0 001A DC Current A 99 99 A 0 01 A 0 8 3 999 9 A 0 1 A AC Current mA A 999 9mA 0 1mA 1 2 3 9 999A 0 001A AC Current A 99 99 A 0 01 A 1 0 3 999 9 A 0 1 A Resistance 99 99 0 01 1 0 3 999 9 0 1 0 5 3...

Страница 26: ...001nF 5 0 20 99 99nF 0 01nF 2 0 5 999 9nF 0 1nF 9 999 F 0 001 F 99 99 F 0 01 F 999 9 F 0 1 F 9 999mF 0 001mF 5 0 5 Frequency 99 99Hz 0 01Hz 0 1 2 999 9Hz 0 1Hz 9 999kHz 0 001kHz 99 99kHz 0 01kHz 999 9...

Страница 27: ...23 Function Range Resolution Accuracy Temperature 20 1000 1 2 5 5 4 1832 1 Diode Continuity NCV...