background image

 

 

Group 3 for notifications to Z-Wave devices associated in this group. Supported command 
classes: 
NOTIFICATION_REPORT 
 
Group 4 for notifications to Z-Wave devices associated in this group. Supported command 
classes: 
SENSOR_BINARY_REPORT 
 
Please refer to your controller's user guide for advanced programming instructions as they 
are a little different for every software. 
 
ADVANCED SETTINGS 
If your controller’s software allows for advanced configuration and parameter adjustment, 
you will be able to change and save the settings below and customize the Contact Sensor’s 
performance to serve your needs. 
 
Trigger Delay 
Parameter 1: Set the delay time for turning associated devices OFF based on status change of 
your Contact Sensor. The number entered as the value corresponds to the number of 
seconds. So if 0 is entered by default, the Contact Sensor will report status change and trigger 
an associated device to turn off instantly, without any delay. If you change this setting to 10, 
the sensor will only trigger the associated device after 10 seconds the status change is 
reported - if your door or window is closed, the light will not go off for another 10 seconds. 
Values: 1 –

 

65536 (seconds). 0 (seconds) –

 

default setting. 

Size: 2 byte dec. 
 
Trigger Action 
Parameter 2: You can choose if your Contact Sensor turns an associated device on or off when 
sending the basic set command. Use value 0 to turn the associated device OFF and value 255 
to turn it ON. Adjust brightness level for a Z-Wave dimmer (Multilevel switch) by putting in any 
value between 1 and 99.  
Values: 0 –

 

OFF; 1 –

 

99 (% of light); 255 – ON (default). 

Size: 1 byte dec. 
 
How to read the LED indicator? 
Slow blink = Contact Sensor is powered on and NOT included to Z-Wave network 
Fast blink = Contact Sensor is in inclusion mode 
Fast flash = Contact Sensor is powered on and included to Z-Wave network 
Single flash = Contact Sensor indicates status change (door opened or closed); sensor 
indicates successful factory reset 
 
MOUNTING 
There are 2 ways to mount the Contact Sensor on your door or window frame: 
 
1. Use the supplied screws to mount the sensor to door / window frame (recommended) and 
the magnet to the moving part of your door / window.  
 
OR 
 

Содержание ZSE08

Страница 1: ...enarios when included to a Z Wave gateway controller Low battery alerts Z Wave Plus with improved 500 chip for faster and safer wireless communication Discreet compact design SPECIFICATIONS Model Number ZSE08 Z Wave Signal Frequency 908 42 MHz Power 1 CR2 battery included Power Consumption 0 13W Operating Temperature 32 104 F Range Up to 100 feet line of sight Installation and Use Indoor only Dime...

Страница 2: ...every day of the year ask getzooz com Get more helpful tips at getzooz com INSTALLATION WAIT Include the open close sensor to your Z Wave network before mounting it Z WAVE INCLUSION 1 Bring the Contact Sensor within direct range of your controller 2 Carefully remove the cover from your Contact Sensor 3 Remove the plastic pull tab from the battery slot The LED indicator will blink slowly 4 Put your...

Страница 3: ...OTE All previously recorded activity and custom settings will be erased from the device s memory WAKE UP MODE If you change settings and parameters for the sensor you may need to wake it up manually for the changes to be recorded Press and release the Z Wave button ONCE to wake the device up The LED indicator will flash ONCE The sensor s wake up interval is set to 12 hours by default to save batte...

Страница 4: ...e sensor will only trigger the associated device after 10 seconds the status change is reported if your door or window is closed the light will not go off for another 10 seconds Values 1 65536 seconds 0 seconds default setting Size 2 byte dec Trigger Action Parameter 2 You can choose if your Contact Sensor turns an associated device on or off when sending the basic set command Use value 0 to turn ...

Страница 5: ...r battery change Z WAVE PLUS CERTIFIED This product can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network WARRANTY This Limited Warranty applies to physical goods and only for physical...

Страница 6: ... WHETHER BASED ON NEGLIGENCE STRICT LIABILITY BREACH OF WARRANTY BREACH OF AGREEMENT OR EQUITABLE PRINCIPLES IS EXPRESSLY LIMITED TO AT ZOOZ S OPTION REPLACEMENT OF OR REPAYMENT OF THE PURCHASE PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MAD...

Страница 7: ...rect the interference by taking one or more of the following measures Reorient or relocate receiving antenna Increase the separation between equipment and receiver Connect equipment into a separate outlet or circuit from receiver Consult the dealer or an experienced radio TV technician for additional assistance All brand names displayed are trademarks of their respective holders c Zooz 2016 ...

Отзывы: