PARTS ENCLOSED:
A.
Fogger Base Assembly
B.
Water Bottle
(one liter capacity)
C.
Hose Nozzle
Attachment
D.
Adjustable Hose
(Adjusts from 10”
to 32” in length)
E.
“No Spill” Valve
A
B
C
D
E
ZOO MED LABORATORIES, INC.
3650 Sacramento Dr. • San Luis Obispo, CA 93401 U.S.A. • Phone: 805-542-9988 • Fax: 805-542-9295 • E-mail: [email protected]
www.zoomed.com
ASSEMBLY & OPERATION:
1. Remove contents from package and inspect for damage. If any parts are missing or damaged, contact Zoo Med’s customer service
department at [email protected] or (888) 496-6633.
2. Place the Fogger Base Assembly
(A)
in the desired location, next to your terrarium but
away from direct sunlight.
3. Wash the water bottle
(B)
with a mild dish soap solution, rinse well, and dry.
4. Fill the Water Bottle
(B)
with clean water. Note: For best results, use distilled water. Mineral deposits from “hard water” will
accumulate on the transducer plate and shorten the life of the fogger.
5. Screw the “No Spill” Valve
(E)
onto the water bottle and insert the water bottle
(B)
into the hole on the left side of the
Fogger Base Assembly
(A)
.
6. Place the Hose Nozzle Attachment
(C)
on the right side of the Fogger Base Assembly
(A)
. Attach the Adjustable Hose
(D)
to the
nozzle
(C)
and route the hose into the terrarium. Be sure that the Hose Nozzle Attachment is firmly seated on the Fogger Base
Assembly
(A)
.
7. Plug the fogger in and turn it on using the dial on the front of the unit. Adjust the fog output using the dial until the desired
level is achieved. It is best to use the Repti Fogger™ in conjunction with Zoo Med’s New HYGROTHERM™ automatic Humidity and
Temperature Controller.
8. Zoo Med’s REPTI FOGGER™ Terrarium Humidifier is equipped with an automatic shut-off feature that turns the fogger off when the
water reservoir is empty.
9. When refilling the water bottle, turn the unit off prior to removing the bottle and “no-spill” valve from the fogger base.
HELPFUL HINTS:
• Using ordinary tap water may shorten the life of your fogger. Zoo Med recommends using distilled water to prevent deposits from
forming on the transducer plate.
• For best results, plug the fogger into Zoo Med’s HYGROTHERM™ Humidity and Temperature Controller (item HT-10) for precise
humidity control in your terrarium or plug the fogger into a timer that turns the fogger on and off throughout the day to maintain
your desired humidity level. Operating the fogger in the “ON” mode for 24 hours per day will
REDUCE
the life span of the fogger.