ZonarSound DCLA 100 Скачать руководство пользователя страница 8

Buffered LL
Audio Output

Slave

Speaker

Outputs

Gain Adjust Header

Internal Speaker

Connection

+1

+2

+3

Gain Adjust Header

Amplifier gain setting
(for unbalanced audio):

Header fitted in LO position:  0dB.

Page 8

Each of the connection options are described below:

24 Vdc Out to Next Master Panel

If additional Master panels are to be powered from the
same supply, use the 24Vdc power terminal block.

+24Vdc

0v

The ZonarSound System

 Installation Manual

Issue 01

4.3.2. Connecting Master Panel Outputs

ALWAYS DISCONNECT THE POWER SOURCE BEFORE MAKING OR REMOVING ANY
CONNECTIONS

The inputs to the Master panel are made on the outside of the amplifier cover plate as
described in section 4.3.1. To connect outputs to other Master panels and to Slave panels,
remove the amplifier cover plate by removing the four cover retaining screws. Carefully
lift off the cover and PCB assembly to allow access to the internal connectors. The
terminal blocks are shown in the diagram below:

LL Audio Output

Содержание DCLA 100

Страница 1: ...by Warwick Audio Technologies Ltd The speaker panels operate in a Master Slave mode and only require an audio signal input and power supply to the Master panel Speaker panels can be connected in a dai...

Страница 2: ...ion Options 4 3 3 DCLA 100 with Slave Speaker Panels LL Audio Source 5 4 Installing Speaker Panels 6 4 1 Preparing the Speaker Panel Support 6 4 2 Fitting the Speaker Panels 7 4 3 Connecting and Confi...

Страница 3: ...c at the input to the ZonarSound system from a 24VDC supply 9 The devices are designed for internal use only Do not fit the units near heat or moisture sources 10 Ensure all connections and cables are...

Страница 4: ...signal 100m Refer to section 4 for installation instructions for these products MP SP Maximum of 3 SPs per MP HV Audio Source LL Audio 24Vdc PSU 100 metres in total Key LL Line Level up to 3V Pk Pk H...

Страница 5: ...Source 24Vdc PSU DCLA 100 HV Volume Audio Output Fault Power Maximum of 4 SPs per DCLA100 100 metres in total Refer to section 4 for installation instructions for the speakers Refer to section 5 for...

Страница 6: ...to the top of the speaker panels The speaker panels can be supported by the suspended ceiling framework but ZonarSound recommends that additional support is provided for each panel by suspending it f...

Страница 7: ...re Note Avoid supporting the panel in the centre during fitment 4 3 Connecting and Configuring the Speaker Panels 4 3 1 Connecting a Standalone Master Panel When a Master panel is used on its own it c...

Страница 8: ...k 24Vdc 0v The ZonarSound System Installation Manual Issue 01 4 3 2 Connecting Master Panel Outputs ALWAYS DISCONNECT THE POWER SOURCE BEFORE MAKING OR REMOVING ANY CONNECTIONS The inputs to the Maste...

Страница 9: ...ust not exceed 10m Using a Balanced Audio Source 4 3 4 The LL audio output to the next Master where required can be either buffered or unbuffered Connect to the appropriate output as shown Remember th...

Страница 10: ...al Speaker Connection Master Output 1 Do not connect Do not connect Output to 2 slave panels in a daisy chain or star configuration The ZonarSound System Installation Manual Issue 01 4 3 5 Connecting...

Страница 11: ...Star Connection Two audio signal connectors enable daisy chain or star configuration Edge Clamper Once all internal cable connections have been made to Master and Slave panels secure them by pushing...

Страница 12: ...individual Slave panel can be set lower than the Master by adjusting its volume control The Slave panel can never be louder than the Master panel 4 3 7 Indicators The LED indicators on the upper face...

Страница 13: ...er panel amplifier to produce the HV output required by Slave panels The Amplifier can be placed in a location close to the audio source and it s HV output can drive up to four Slave panels connected...

Страница 14: ...ol The Slave panel can never be louder than the volume set on the master volume control 5 3 Indicators The LED indicators on the front of the Amplifier box are as follows Name Colour Function Audio Bl...

Страница 15: ...e following standards EN 60065 2002 A11 2008 Audio video and similar electronic apparatus Safety requirements EN 55013 2001 A1 2003 A2 2006 Sound and television broadcast receivers and associated equi...

Страница 16: ...Max SPL 90 dB 2 kHz 2 m 1 V RMS input THD 5 85 dB 2 m Master audio input connection Screw Terminal Balanced or un balanced Master Panel volume control 0dB to Max SPL Master Panel input gain selection...

Отзывы: