Zonar Zonar Connect Скачать руководство пользователя страница 14

 

Zonar Connect

®  

Installation/User Guide 

 

Mounting & Operation 

 
Mounting position considerations:

 

 
1)   Verify placement acceptability with state DOT/Law   Enforcement prior to installation. 
2)   Follow all general guidelines on page 12. 
 

Do: 

1)  Mount in the vehicle at a convenient height and angle for drivers and co-drivers to access. 
2) Ensure location of the installed Zonar Connect does not block driver view (including mirrors and gauges) 

or 

interfere with vehicle safe operation of the vehicle’s controls. 

3)  Ensure that the placement of the Zonar Connect allows drivers/co-drivers to easily dock and undock 

the tablet. 

4)  Ensure mounting surface is strong enough to support RAM mount and the Zonar Connect. 
5)  Choose a location which does not impede driver/co-driver entry 
6)  Choose a location which is within easy reach of driver / co-driver, and within normal line-of-sight. 
7.  Lay all components out prior to installation to check for cable length and interference issues. 
 

Don’t: 

1)  Do not mount the Zonar Connect in an area that may interfere with the deployment of an air bag. 
2)  Do not install the Zonar Connect in a location that may impact the driver /co-driver in the event of an 

accident or sudden stop. 

3)  Do not mount the Zonar Connect in dirty or wet areas. 
4)  Do not mount the Zonar Connect in areas of direct sunlight 
5)  Do not install the Zonar Connect in front of an open AC or heater vent. If unable to install elsewhere, 

close the louvered vent the Zonar Connect is installed in front of. 

6)  Do not install the Zonar Connect near windows and vents which may pass rain water. 
7)  Avoid mounting the Zonar Connect in an area that may limit leg room or where the Zonar Connect may 

likely be used as foot, elbow, etc. rest. 

 

Mounting Installation

 

 
Refer to mounting locations guide (see Fig. 15-1) for examples of ideal mounting locations. Mounting 
locations may vary based on the type of vehicle or driver requirements. 
1)  Attach RAM mount to a location visible and accessible to the driver. 
2)  Use backing plate to secure mount. 
 
 

Содержание Zonar Connect

Страница 1: ...REV 09 16 16 ...

Страница 2: ...While we attempt to point out the most common installation questions and issues common sense good housekeeping procedures attention to detail safety adherence and technical competence of the professional installer are critical for a successful installation Please refer to your specific vehicle manufacturer guidelines for the installation of electrical components and wiring Details on operating the...

Страница 3: ...onnect Installation Example 16 System Installation Diagram 17 System Check 18 Warranty Notices FCC Compliance 19 21 2016 Zonar Systems EVIR Z Pass Ground Traffic Control and V3 are trademarks of Zonar Systems RAM and WI FI are third party registered trademarks of National Products Inc and WI FI Alliance respectively All Rights Reserved Products and services protected by one or more of the followin...

Страница 4: ...t Installation User Guide System Overview Real Time Delivery of Engine Condition and Performance Data Driver Performance and Location Zonar Secure Services Encrypted Data Transmissions to Customer On Site Location ...

Страница 5: ...ional information The Zonar Connect helps automate common processes offering the flexibility to create custom applications and integrating to maximize operational value Zonar s Zonar Connect Tablet features include Driver Hours of Service Verified Electronic Vehicle Inspections Two Way Messaging Advanced navigation Visual driver feedback via the My Driving application Camera and video for document...

Страница 6: ...rson authorized by that party to use and or install the Product that has either a purchased the Product or b leased the Product from Zonar Systems Inc or its related companies The Owner of this product is solely responsible for observing safe driving practices The choice location and installation of all components of the Product is critical If installation is not correct the Product may not perfor...

Страница 7: ...dity 95 R H non condensing Shock Vibration SAE J1455 MIL STD 202G EMC EMI SAE J1113 ESD IEC 61000 4 2 IP Rating 54 RFID Frequency 125 kHz Read Range 0 to 1 inch Electrical Battery 2760 mAh lithium ion VOLTAGE Operating Voltage 8 VDC to 30 VDC vehicle battery Typical current draw State Draw Charge disabled 1 mA Charge enabled Zonar Connect off 23 300mA Typical normal Zonar Connect operation 400 600...

Страница 8: ...ect vehicle battery suggested 13 6 Disconnect 4 Pin connector at rear of V3 13 7 Layout the Zonar Connect hardware and cables to desired location 13 8 Install RAM mount and backing plate 13 9 Route and connect the Zonar Connect Power Data cable 13 10 Re connect vehicle battery 13 11 Connect 4 Pin power connector into V3 13 12 Start engine 13 Ensure V3 has 3 solid Green LED s 13 14 Snap the Zonar C...

Страница 9: ...or any V3 or Zonar Connect issues you may encounter Prerequisites 1 The V3 GPS unit must be fully installed configured checked out and fully operational prior to installing the Zonar Connect Please see the V3 Installation and User Guide on Zonar s support website 2 The Zonar Connect requires coordination between Zonar and the customer for software setup Please see Zonar s Initial Setup Checklist o...

Страница 10: ...Equipment A Zonar s Zonar Connect Tablet B The Zonar Connect Dock C RAM Mount with Mounting Screws and Aluminum Backing Plate D V3 E Zonar Connect Power Serial Cable F AC DC Power Adaptor output 5V 2 5A with a micro USB cable optional To Wall F ...

Страница 11: ...Zonar Connect Installation User Guide Equipment Dimensions ...

Страница 12: ... when the vehicle is in reverse The Zonar Connect screen will automatically switch between computer and video display mode without user interaction While hooking a video feed from a backup camera into the Zonar Connect may can provide a safety benefit video feeds have the potential to be very distracting Zonar strongly recommends that customers implement a thorough safety review before deciding to...

Страница 13: ...s of cables 3 Avoid moving components e g doors steering shafts handles fans etc 4 Provide an adequate Service Loop i e cable slack to allow for servicing of equipment 5 Avoid routing cables thru doors windows and other pinch points 6 Avoid routing cables in high personnel traffic areas 7 Avoid routing antenna cables near radio and PA equipment CORRECT Bend radius adequate Hole has grommet General...

Страница 14: ...tion to check for cable length and interference issues Don t 1 Do not mount the Zonar Connect in an area that may interfere with the deployment of an air bag 2 Do not install the Zonar Connect in a location that may impact the driver co driver in the event of an accident or sudden stop 3 Do not mount the Zonar Connect in dirty or wet areas 4 Do not mount the Zonar Connect in areas of direct sunlig...

Страница 15: ...ct s applications and software please refer to the User s Guide Quick Start Guide or the built in Help Documents specific to the application Operational Notes 1 The Zonar Connect requires a V3 to operate 2 The Zonar Connect must be fully docked in order to send data to Zonar servers 3 Sleep Modes A The Zonar Connect enters sleep mode after 2 minutes of inactivity This timeout can be adjusted to 30...

Страница 16: ...Zonar Connect Installation User Guide Installation Example Figure 15 1 ...

Страница 17: ...Zonar Connect Installation User Guide System Installation Diagram ...

Страница 18: ...System Installation Diagram In door usage Power Adapter USB Cable Part 20083 20084 Cable Length 1 5meter To Wall ...

Страница 19: ...ore of the following applications A Zlogs Hours of Service application B Navigation Mapping and turn by turn direction application C Messaging Two way communication between Asset and Dispatcher d EVIR Asset inspection application 6 Application checkout A ZLogs Not required B Navigation Open application ensure map is oriented to your location This ensures the V3 is properly passing Latitude Longitu...

Страница 20: ...ct returned is determined to be damaged due to any of the aforementioned circumstances the Customer will be charged the price of a refurbished unit plus shipping and handling CUSTOMER S SOLE AND EXCLUSIVE REMEDY AND ZONAR S ENTIRE OBLIGATION UNDER THESE LIMITED WARRANTIES for defective equipment is the repair and replacement of the equipment free of charge by Zonar Zonar shall not be liable to Cus...

Страница 21: ...n with any other antenna or transmitter End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance For product available in the USA Canada market only channel 1 11 can be operated Selection of other channels is not possible FCC RF Radiation Exposure Statement Portable Device This equipment complies wit...

Отзывы: