General Guidelines
Drill Holes
1) Do not drill into the Zonar Connect or the Zonar Connect dock unit. This will void the warranty.
2) Capture all drill chips during drilling operations. Do not allow chips to fall onto equipment,
furnishings, etc.
3) Deburr all drill holes on both sides of drilled surface. Example deburr tool:
4) All drill holes must have a rubber grommet or similar anti-chaffing system installed to protect
cable assemblies (e.g. plastic conduit).
5) Seal all penetration drill holes which may pass rain water.
Cable Management
1) Strain relieve and support all cable installations.
2) Avoid sharp bends and tight radius installations of cables.
3) Avoid moving components (e.g. doors, steering shafts, handles, fans, etc.).
4) Provide an adequate
“Service Loop” i.e. “cable slack” to allow for servicing of equipment.
5) Avoid routing cables thru doors, windows, and other pinch points.
6) Avoid routing cables in high personnel traffic areas.
7) Avoid routing antenna cables near radio and PA equipment.
CORRECT
• Bend radius adequate•
• Hole has grommet
General Housekeeping
1) Capture all drill chips during drilling operations. Do not allow drill chips to fall onto electrical
equipment, furnishings, heating ducts, etc. Magnets, sticky tape, vacuums, physical barriers,
etc. may all be used to accomplish this task.
2) Remove excess sealant. Sealant should be debris/contaminant free (e.g. drill chips),
consistent, and uniform in appearance.
3) Clip excess wire tie protrusions.
INCORRECT
• Bend radius too tight
• Hole has sharp edges
• Hole has no grommet