background image

© 2013 Zonar Systems • All Rights Reserved.

REV:02/14/13

V3R™ USERS MANUAL

& INSTALLATION GUIDE

Содержание V3R

Страница 1: ...REV 02 14 13...

Страница 2: ...tallation questions and issues common sense good housekeeping procedures attention to detail safety adherence and technical competence of the professional installer is critical for a successful instal...

Страница 3: ...nd Specifications 13 Installation Examples 14 System Installation Diagram 15 Troubleshooting 16 17 Warranty Notices FCC Compliance 18 TABLE OF CONTENTS 3 2013 Zonar Systems EVIR ZPass Ground Traffic C...

Страница 4: ...SYSTEM OVERVIEW 4 CUSTOMER On Site Location ZONAR Secure Servers CELL TOWER INTERNET...

Страница 5: ...V3R EQUIPMENT 5 Fuse Holders ATC Style Fuses Crimpable Butt Splices V3R POWER CABLE ZONAR V3R INSTALLATION HARDWARE Mounting Hardware...

Страница 6: ...using To do so will void the warranty and possibly lead to moisture intrusion Drill Holes 1 Do not drill into the V3R unit This will void the warranty 2 Capture all drill chips during drilling operati...

Страница 7: ...s in the location you have installed the V3R this should satisfy the GSM Cellular requirements of the V3R Fig 7 1 4 Mount onto interior flat surface large enough to accommodate footprint 5 Avoid mount...

Страница 8: ...er 7 Power Bundle wiring 4 Pin 3 wires A Red Constant DC 8 VDC 30 VDC dependent on system type B Black Ground must be less than 1 ohm measure from 4 Pin connector to chassis attachment point C White S...

Страница 9: ...possible to use an empty location ensure that the existing fuse is placed in the correct location on the fuse tap See Fig 9 1 Whenever it is not possible to utilize Add a Circuit fuse taps then the po...

Страница 10: ...1 5 Ensure a clear antenna view of the open sky 6 Maintain a minimum of 6 inches from any rooftop edge or ledge see Fig 10 1 7 Drill deburr grommet weather seal cable thru hole as required Drill hole...

Страница 11: ...onstant power will lead to high and inaccurate idle times B Remove inline fuse on switched power White wire and measure voltage at fuse holder Engine running 8 to 30 VDC Engine Off 0 Volts 4 Final che...

Страница 12: ...ps captured Cable Management All cables properly ran tight radius interference strain relieved supported service looped Electrical System hookup complies to your established standard Red lead voltage...

Страница 13: ...tion of all components of the Product is critical If installation is not correct the Product may not perform at its designed potential or specifications If in doubt consult your vehicle s manufacturer...

Страница 14: ...High Mount Alternate Yellow Iron Top of Cab Preferred Yellow Iron Inside Back Cab Alternate Min 8 from Operator External GPS Antenna Required Note The V3R needs a clear view to the open sky to track G...

Страница 15: ...10006 Cable Length 16 5 ft Switched Power White GND Black Constant Power Supply Input Voltage 8 30VDC Engine Running 8 30 VDC Acc Accessory mode Engine Not Running 0 VDC 12VDC Red 3A 5A SYSTEM INSTAL...

Страница 16: ...3R GPS unit Therefore typical V3R issues can arise with any V3R Since much of the V3R troubleshooting information references LEDs which are hidden inside the waterproof V3R enclosure in most cases you...

Страница 17: ...4 Connect the negative meter probe to Zonar GND wire 5 Refer to Figure 1 16 and locate the V pin on the 35 pin connector Probe this pin with the positive meter probe 6 To pass the inspection the volta...

Страница 18: ...ess arising out of Zonar s Subscription Agreement Warning Part 15 21 Changes or modifications not expressly approved by Zonar Systems could void the user s authority to operate the equipment Caution R...

Страница 19: ...NOTES 19...

Страница 20: ...2013 Zonar Systems All Rights Reserved REV 02 14 13 V3R USERS MANUAL INSTALLATION GUIDE...