ZOLL Invasive Blood Pressure Скачать руководство пользователя страница 21

ZOLL M Series Invasive Blood Pressure

15

Software License

Read this License agreement carefully before operating any of the M Series products.
Software incorporated into the system is protected by copyright laws and international copyright treaties as well as other 
intellectual property laws and treaties. This software is licensed, not sold. By taking delivery of and using this system, the 
Purchaser signifies agreement to and acceptance of the following terms and conditions:
Grant of License: In consideration of payment of the software license fee which is part of the price paid for this product ZOLL 
Medical Corporation grants the Purchaser a non-exclusive license, without right to sublicense, to use the system software in 
object-code form only.
Ownership of Software/Firmware: Title to, ownership of and all rights and interests in the system software and all copies thereof 
remain at all times vested in the manufacturer, and Licensors to ZOLL Medical Corporation and they do not pass to Purchaser.
Assignment: Purchaser agrees not to assign, sub-license or otherwise transfer or share its rights under the license without the 
express written permission of ZOLL Medical Corporation.
Use Restrictions: As the Purchaser, you may physically transfer the products from one location to another provided that the 
software/firmware is not copied. You may not disclose, publish, translate, release or distribute copies of the software/firmware 
to others. You may not modify, adapt, translate, reverse engineer, decompile, crosscompile, disassemble or create derivative 
works based on the software/firmware. 
No Implied License
Possession or purchase of this device does not convey any express or implied license to use the device with replacement parts 
which would, alone, or in combination with this device, fall within the scope of one or more of the patents relating to this device.

Содержание Invasive Blood Pressure

Страница 1: ...Invasive Blood Pressure 9650 0219 01 Rev D...

Страница 2: ...ssue date or revision level for this operation guide is shown on the front cover ZOLL and M Series are registered trademarks of ZOLL Medical Corporation 2007 by ZOLL Medical Corporation All rights res...

Страница 3: ...2 Connecting the transducer to the unit 2 Setting up the transducer and catheter 3 Displaying the IBP Menu 3 Zeroing the Transducer 4 TAKING MEASUREMENTS 5 Reading the Display 6 Changing the Display 8...

Страница 4: ...iv ZOLL M Series Invasive Blood Pressure This page intentionally left blank...

Страница 5: ...n the presence of oxygen rich atmospheres flammable anesthetics or other flammable agents such as gasoline Do not use near the site of a gasoline spill Explosion may result The use of accessories tran...

Страница 6: ...efibrillation Using the IBP option introduces no risk of burns due to electro surgery Do not reuse single use transducers Check the transducer packaging to make certain the transducer is sterile Check...

Страница 7: ...llow your hospital s protocol for setting up the transducer and catheter 4 Display the IBP menu 5 Zero the transducer 6 Select the desired labels and ranges for each trace if present settings are not...

Страница 8: ...ing a transducer Use only disposable or reusable transducers with 5uV V mmHg sensitivity See Ordering Accessories on page 16 for a list of ZOLL approved transducers WARNING The use of accessories tran...

Страница 9: ...o the transducer you must first display the IBP menu You can display the IBP menu without leaving Monitor Defib or Pacer mode AEDs must be in manual mode to display the IBP menu See the M Series Opera...

Страница 10: ...e transducer stopcock to the patient 3 Open the venting stopcock to atmospheric air 4 Allow a few seconds for the transducer to settle 5 Press the Zero softkey If the Zero softkey is not displayed see...

Страница 11: ...n mind that the following conditions can influence IBP measurement accuracy Catheter placement in the vasculature Artifact such as catheter whip should be handled per your established clinical protoco...

Страница 12: ...ee traces Trace 1 reserved for ECG Trace 2 Pressure channel 1 or EtCO2 SpO2 3 Lead ECG if selected Trace 3 Pressure channel 2 or EtCO2 SpO2 3 Lead ECG if selected See Changing the displayed traces on...

Страница 13: ...ent the status of pressure measurements Numbers that represent the measurement values see Fig 6 and Fig 7 Figure 6 IBP Data Display Area ART PA P1 Figure 7 IBP Data Display Area CVP ICP P2 Either chan...

Страница 14: ...e display messages take the place of Trace 3 To select the displayed traces 1 Press the Traces softkey If Trace softkey label is not displayed press the Return softkey until Traces displays The Traces...

Страница 15: ...s to one of the following ART arterial blood pressure PA pulmonary arterial pressure CVP central venous pressure ICP intracranial pressure To change the trace label 1 Press the Label softkey If the La...

Страница 16: ...ed see Displaying the IBP Menu on page 3 The Range menu displays see Fig 12 Figure 12 Range Menu 2 Press the Select softkey to select the pressure channel whose range you want to change 3 Press the En...

Страница 17: ...kPa 45 to 300 mmHg 6 0 to 39 9 kPa Low Systolic 90 mmHg 12 0 kPa 50 to 295 mmHg 6 7 to 39 2 kPa High Diastolic 110 mmHg 14 6 kPa 45 to 300 mmHg 6 0 to 39 9 kPa Low Diastolic 50 mmHg 6 6 kPa 50 to 295...

Страница 18: ...other alarms for that channel to the same status For example if you enable the Pressure channel 1 systolic alarm all other Pressure channel 1 alarms are automatically enabled Or if you disable the Pr...

Страница 19: ...ld be performed daily to ensure that the IBP option is functioning properly In addition this daily checkout procedure ensures that medical personnel maintain familiarity with the proper use of the IBP...

Страница 20: ...to 20 Hz Noise 1 mmHg peak to peak Transducer Impedances Input minimum 250 Output maximum 3000 Transducer Excitation 2 5 V DC Table 7 Battery Operating Time Specifications using ZOLL XL Battery Pack...

Страница 21: ...in the system software and all copies thereof remain at all times vested in the manufacturer and Licensors to ZOLL Medical Corporation and they do not pass to Purchaser Assignment Purchaser agrees no...

Страница 22: ...A Abbott Critical Care Systems North Chicago IL 60064 800 222 6883 Baxter Edwards TruWave N A Baxter Edwards Lifesciences LLC One Edwards Way Irvine CA 92614 949 250 2500 Utah Medical Deltran IV 8000...

Страница 23: ...X No communication from the IBP processor BP processor failed self test Turn unit off wait 10 seconds and retry If problem persists return unit to ZOLL Technical Service REPLACE P1 TRANSDUCER REPLACE...

Страница 24: ...bubbles including pinpoint air bubbles from the fluid circuit Pressure readings too high or too low after verification of non physiologic changes in patient Air bubbles in the fluid Clotted blood at c...

Страница 25: ...v F Features of IBP option listed 1 H Heartrate type of reading displayed 7 Humidity specification 14 I IBP contraindications vi factors that influence measurement accuracy 5 features of 1 how it wor...

Страница 26: ...m v SYSTEM FAULT message significance of 17 Systolic Blood Pressure reading on display 7 T Temperature operating 14 shipping 14 storing 14 Trace changing displayed 8 changing displayed range 10 changi...