background image

Page: 1/17

YPO2

-09C 

Portable Air Conditioner

 User's  Manual

Содержание YPO2-09C

Страница 1: ...Page 1 17 YPO2 09C Portable Air Conditioner User s Manual...

Страница 2: ...Water Drainage Methods 12 Maintenance 13 End of Season Storage 15 Handling of the Unit 14 Troubleshooting 16 Appendix 17 Thank you for selecting this super quality air conditioner Please keep this Use...

Страница 3: ...ction of the drain pipe is in good condition without flexure When adjusting the horizontal vertical louver at the air outlet turn it slightly by hand to avoid damage of the louvre Keep the unit in an...

Страница 4: ...OFF setting Features and Parts 1 Features Brand new appearance compact structure with a sense of streamline The appearance of the unit is beautiful and elegant the remote control can be placed on the...

Страница 5: ...oner in an upright position for at least 2 hours before first use This air conditioner may be moved indoor conveniently leave the air conditioner in an upright position while moving it The air conditi...

Страница 6: ...t of the back shell and the C shape buckle of the heat exhaust hose 1 3 Installation of the heat exhaust hose assembly and unit 1 Pull the end of the heat exhaust hose apart by several turns 2 Hold th...

Страница 7: ...ust the distance of the window sealing board assembly pulled apart so that the two ends of the assembly come into contact with the window frame and fasten the parts of the assembly with copper screws...

Страница 8: ...structions of the control panel 1 Select the operation interface depending on the models and functions The operation interfaces of the cooling only and cooling heating models are as follows 1 Cooling...

Страница 9: ...mpressor shuts down When the ambient temperature rises to be 17 the compressor starts again The start stop of the compressor meets the requirement for 3 minute protection time The fan is forced to swi...

Страница 10: ...ton to decrease the temperature and timing value 7 F button press this button to switch between the Celsius degree and Fahrenheit degree 8 Cool button press this button to set this unit to operate in...

Страница 11: ...inutes continuously the unit enters fluorine free protection the compressor and water spraying motor turn off the fan operates in the low speed mode and E3 is displayed Remote Control 1 2 3 4 5 6 7 C...

Страница 12: ...p tightly Note 1 Turn on the unit only after the water plug and drain cap are installed properly otherwise the condensate of the unit will flow onto the ground or carpet Drain cap Water plug Figure 12...

Страница 13: ...ilter frame gently in the direction shown by the arrow as shown in Figure 12 2 Grip the gripping position of the evaporator filter mesh and condenser filter mesh and take out the filter mesh gently in...

Страница 14: ...ame in the reverse order of removal Be sure to install the filter mesh first before the filter frame is installed 2 Install the filter frame gently so as not to damage it 3 Cleaning of the handle posi...

Страница 15: ...g the power plug wrap the power cord around the wire winding post insert the plug into the universal jack at the back shell of the unit install the water plug and drain cap 4 Remove the heat exhaust h...

Страница 16: ...dirty Clean or replace the filter mesh Air inlet or air outlet clogged Remove the obstruction Large noise Air conditioner not put on a flat surface Put the air conditioner in a flat and firm place may...

Страница 17: ...gram of the air conditioner For specific technical parameters of the models refer to the nameplate on the product s Disposal do not store waste products with other non classified wastes Such wastes sh...

Отзывы: