Template machine - Touch screen E2
I
nformation
80
Under
the
[information]
interface,
press
the
"
add or subtract counter" button to enter the
[counter] setting interface.
Sewing counter:
add/subtract 1 counter per sewing item.
Piece counter:
add/subtract 1 counter per sewing cycle.
Piece counter is mainly for C pattern counting, if other
sewing types are used, piece counter and sewing counter
function the same.
1
Ð
Counter value setting
Press to set the current value of the counter.
After pressing the button, the counter can be
set. When the set value is 0, the counter will not work.
2
Ð
Counter type setting
Set to counter type, when the current value
reaches the set value will prompt an alarm.
Set to decrement counter type to alert when
current value is 0.
Turn off the counter function.
Note:
parameter u12-4: prohibit counter from being modified. If
set to "prohibit modification", the interface cannot be entered.
Note:
parameter u12-5: operation of the sewing machine when
the counter reaches the set value. If it is set as "sewing can
continue", the current value of the counter will overflow without
alarming, and will automatically return to the target value
(adding counter returns to 0, and subtracting counter returns to
the set value).
7.6 Run Note