Error solution steps
•
Check the impedance between two legs of mercury switch U5 when the main board is
in upright position: around 11.7K; If the main board is in horizontal position the mercury
switch will be short circuit and the impedance: 0
Ω
•
Check the impedance of C51 on main board: around 10K; supply power of 80V by
isolation transformer, the voltage is:3.2V
•
If the mercury is not working, access control box’s parameter interface,set the
parameter No.10 to value 1.
E19---
(
Turn over warn: turn over switch is effective
)
C51
U5
ERROR SOLUTION