© Copyright 2019 Zoeller
®
Co. All rights reserved.
QWIK JON® ULTIMA 202 SYSTEMS
INSTALLATION INSTRUCTIONS
1. To reduce the risk of electrical shock, a properly grounded receptacle or
control box of grounding type must be installed and protected by a ground
fault circuit interrupter (GFCI) in accordance with the National Electrical Code
and applicable local codes. Never remove ground pin from plug.
2. Make certain that the ground fault interrupter protected receptacle is within
reach of the pump’s power supply cord. DO NOT USE AN EXTENSION CORD.
Extension cords that are too long or too light do not deliver sufficient voltage
to the pump motor and could present a safety hazard if the insulation were
to become damaged or the connection end were to fall into a damp or wet
area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit, sized according to
the National Electrical Code for the current shown on the pump name plate,
is recommended.
4. Testing for ground. As a safety measure, each electrical outlet should be
checked for ground using an Underwriters Laboratory Listed circuit analyzer
which will indicate if the power, neutral and ground wires are correctly
connected to your outlet. If they are not, call a qualified, licensed electrician.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. If pump is wired direct, de-energize the circuit
at the control box. Grounded pumps are supplied with a 3-prong grounded
plug to help protect you against the possibility of electrical shock. DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN. To reduce the
risk of electrical shock, a properly grounded receptacle of grounding type
must be installed and protected by a ground fault circuit interrupter (GFCI) or
residual current device (RCD) in accordance with National Electrical Code
and applicable local codes.
6. Installation and servicing of electrical circuits and hardware should only be
performed by a qualified, licensed electrician.
7. Check to be sure your power source is adequate to handle the amperage
requirements of the motor as indicated on the pump or name plate.
NOTICE TO INSTALLER: Instructions must remain with installation.
FM2369
0819
Supersedes
0518
P/N 018507
MODEL NO. ____________________
DATE CODE: __________________
DATE INSTALLED: _____________
SEE BELOW FOR LIST OF WARNINGS
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
MAIL TO
: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO
: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL
: (502) 778-2731 • 1 (800) 928-PUMP •
FAX
: (502) 774-3624
Visit our website:
zoellerpumps.com
SAFETY INSTRUCTIONS
REFER TO CAUTIONS AND WARRANTY ON PAGE 2.
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY
DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN THIS
MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a
SAFETY ALERT SYMBOL
. When you see this
symbol on the pump or in the manual, look for one of
the following signal words and be alert to the potential
for personal injury or property damage.
Warns of hazards that
CAN
cause serious personal
injury, death or major property damage.
Warns of hazards that
CAN
cause personal injury or
property damage.
Warns of electrical shock hazards that
CAN
cause
serious personal injury, death or major property
damage.
Identifies any terminal which is intended for
connection to an external conductor for protection
against electrical shock in case of a fault, or the
terminal of a protective earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO
PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
CAUTION
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
DO NOT
remove the test/oil fill plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained
for future reference.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
U.S. Patent Nos.
7,203,976; 9,352,327;
8,562,287
Canadian Patent No.
2,512,023