background image

2

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

LIMITED WARRANTY

TROUBLESHOOTING INFORMATION

Manufacturer warrants, to the purchaser and subsequent owner during the 
warranty period, every new product to be free from defects in material and 
workmanship under normal use and service, when properly used and maintained, 
for a period 3 years (models 508 / 53 and 508 / 98) or 5 years (model 508 / 63) from 
date of purchase by the end user.  Zoeller batteries have a 3 year warranty. Parts 
that fail within the warranty period, that inspections determine to be defective 
in material or workmanship, will be repaired, replaced or remanufactured at 
Manufacturer's option, provided however, that by so doing we will not be obligated 
to replace an entire assembly, the entire mechanism or the complete unit.  No 
allowance will be made for shipping charges, damages, labor or other charges 
that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material 
or product that has been disassembled without prior approval of Manufacturer, 
subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable 
act of nature; that has not been installed, operated or maintained in accordance 
with Manufacturer's installation instructions; that has been exposed to outside 
substances including but not limited to the following:  sand, gravel, cement, mud, 
tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 
abrasive or corrosive substances, wash towels or feminine sanitary products, 

etc. in all pumping applications.  The warranty set out in the paragraph above is 
in lieu of all other warranties expressed or implied; and we do not authorize any 
representative or other person to assume for us any other liability in connection 
with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, Attention: 
Customer Support Department to obtain any needed repair or replacement of 
part(s) or additional information pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL 
OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; 
AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND 
OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED 
WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so 
the above limitation may not apply to you. Some states do not allow the exclusion 
or limitation of incidental or consequential damages, so the above limitation or 
exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

1.  DC Pump won’t run.

 

(a)  Check for proper connections.

 

(b)  Check all wire terminal points. Clean if required.

 

(c)  Check for low battery. Service battery if required.

 

(d)  Check 30 amp fuse on controller (see fig. 5). If fuse is blown, replace with 30 

amp automotive blade fuse.

2.  Pump runs but pumps very little or no water without AC power.

 

(a)   Check for low battery. Battery will recharge if green power “on” light indicates 

power has been restored and the float switch is in the off position.

 

(b)  If immediate usage is required, remove and replace dead battery with a full 

recharged battery.

 

(c)  Due to varying conditions, the pump may continue to run on a low battery 

without sufficient power to remove water.  Pump will not stop running until 

battery is below minimum voltage.

 (d) 

CAUTION

 Weak batteries can be recharged but may not store sufficient 

energy for full service. A weak recharged battery  can only be detected by 

reduced  pumping  time  or  by  professional  load  testing  equipment.  If  your 

emergency pump system is used frequently the battery should be checked 

by a qualified battery dealer.

3.  Pump runs but pumps very little or no water.

 

(a)   Verfiy pump is connected completely.

 

(b)  Check to make sure pump weep hole is clear and unit is not airlocked.

 

(c)   Make sure discharge piping is not blocked.

4.  Pump cycles too frequently.

 

(a)  Check positions of rubber stops on operational float rod.

 

(b)  Adjust  upper  rubber  float  stop  as  required.  Recommended  for  standard 

installation.

5.  Float switch in “on” position for more than 3 seconds. Pump won’t run.

 

(a)  Remove pump. Check for obstruction in pump preventing impeller from rotating.

6.  Pump runs, but pumps water intermittently.

 

(a)  Pump is air locking. Check flow of water incoming to sump. If water is entering 

the sump at a high velocity creating a turbulent condition, a mixture of air and 

water may cause a complete or partial air lock and reduce or stop the flow of 

water in the discharge pipe.

 

(b)  Baffle  the  incoming  stream  of  water  to  reduce  turbulence.  Diverting  water 

stream against wall of basin usually corrects an air lock problem.

7.  Water level stays high. DC Pump continues to run.

    (a)  Battery is low.

    (b)  If power has been restored and water in sump remains high check primary 

pump. Service if required.

     (c)  After several hours the battery will be restored to full charge.

8.  Alarm sounds during battery recharge cycle.

    (a)  To silence alarm if alarm will not reset, unplug the charger from 115 V wall 

outlet, then disconnect the black lead from charger on negative (-) battery post. 

Check battery. Replace if necessary. Reconnect and refer to Installation (step 

12).

NOTE: The Z Control

®

 Cloud may provide additional information.

In instances where property damages are incurred as a result of an alleged product failure, the property 

owner must retain possession of the product for investigation purpose.  

Содержание ProPak AQUANOT FIT 508/53

Страница 1: ...servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electrical shock These pumps have not been investigated for use in swimming pools and marine areas 11 Prop65 Warning for California residents Cancer and Reproductive Harm www P65Warnings ca gov 12 It is the owne...

Страница 2: ...s which vary from state to state 1 DC Pump won t run a Check for proper connections b Check all wire terminal points Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 5 If fuse is blown replace with 30 amp automotive blade fuse 2 Pump runs but pumps very little or no water without AC power a Check for low battery Battery will recharge i...

Страница 3: ...stallation conforms to each of them 11 DO consult manufacturer for clarifications or questions 12 DO inspectandtestsystemforproperoperationsatleasteverythree months Copyright 2019 Zoeller Co All rights reserved ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are wearing insulated protective sole shoes and not standing i...

Страница 4: ...ed Timeforrechargedependsupontheamountofpowerconsumed bythepumpingcycleduringtheACpowerinterruption Thepumpmaygo backtothereadyrunpositioninaveryshortperiodoftime Acompletely drained battery may require up to 24 hours for full recharge If battery does not charge properly the LED battery will flash red PERFORMANCE The DC pump performance at 12 7 Vdc BATTERY SELECTION Discharge Feet of Head 5 1 5 m ...

Страница 5: ...al operating level and shut off b The yellow charging light should be on The charger is replacing the energy consumed during the test The green light will come on after the charger has replaced the energy consumed during the test 3 Add distilled water to battery when necessary per battery manufacturer s instructions CAUTION Battery acid is dangerous Take proper safety precautions Do not splash the...

Страница 6: ... WATER REED SENSOR 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SCREWS INTO PRIMARY PUMP DISCHARGE HAND TIGHTEN ONLY WEEP HOLE MUST BE VISIBLE OPERATIONAL FLOAT SWITCH DC PUMP CLAMP HIGH WATER REED SENSOR CHECK VALVE O RING PRIMARY PUMP CLAMP DC PUMP O RING TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM SK3182 SK3223 FIGURE 2 FIGURE 1 Copyright 2019 Zoeller Co All ...

Страница 7: ...Pipe Pvc 1 5 X 10 Sch 40 1 019509 10 Fuse 30A Automotive Startard 1 016918 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locations SK3185 FIGURE 3 Copyright 2019 Zoeller Co All rights reserved OPERAT...

Страница 8: ...eset will clear flashing light on unit Test Will run the pump to determine if amp draw of pump is in range Controller is factory programmed to self test the pump for several seconds every 24 hours Pressing the test button will start the 24 hour timer for self testing Note Holding both the silence reset and test button at the same time for 5 seconds will cause a factory reset on the controller AQUA...

Страница 9: ...ud com Locate the Fit s Device ID on the top sticker Connection Steps 1 Apply AC power to the Fit The Z Control LED will blink and then turn off indicating the Fit is in AP Mode and is transmitting an SSID see Figure B If the LED is blinking and not in AP mode press the Z Control button for 12 seconds and let go See figure A A pen or toothpick or similar is required to press the Z Control Button T...

Страница 10: ...s capable of OTA or over the air firmware updates It s possible that the Fit could perform an update immediately if one is available at the Z Control Cloud If an update is taking place the Z Control LED will flicker for up to 1 minute while the update is downloaded The Z Control LED will be solid and all other LEDs will turn off while the update is being installed After up to 1 minute the Fit will...

Страница 11: ...etting up WiFi creating an account or adding devices These steps should be done through the web interface using a mobile device to access the web interface is fine 4 Once the Fit s Z Control LED is solid log in to your account or create one at zcontrolcloud com see Figure D Click the Edit button next to a location and choose Add New Device Follow the directions to add your Fit by either auto detec...

Страница 12: ...thatnoCOisbeingproduced achargingbatterymaybeproducinggaseousby productswhicharecausingtheCOdetector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the...

Отзывы: