Zoeller FM2102 Скачать руководство пользователя страница 8

© Copyright 2007 Zoeller Co. All rights reserved.

MAIL TO:

  P.O. BOX 16347

Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road

Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP

FAX (502) 774-3624

Manufacturers of . . 

www.zoeller.com

Typical Installations

ALL INSTALLATIONS REQUIRE A FILTER BEFORE THE PUMP.

SK2220

SK2219

ZOELLER EFFLUENT

TURBINE PUMP

WARNING!

P/N

Z

Z

OELLER

SEPTIC TANK

SEPTIC TANK

ZOELLER EFFLUENT

TURBINE PUMP

!

WARNING
ELECTRICAL SHOCK 
    HAZARD

Z

C

O

Z

P/N 10-1193

REV. A

0ELLER

PUMP CO.

LOUISVILLE, KY

NOTE: Flow must 
be directed around 
the motor for cooling 
on 2 HP and higher 
units.

Содержание FM2102

Страница 1: ...tion Should further assistance be necessary please call our Technical Service department at 1 800 928 PUMP Safety Instructions 1 Limited Warranty 2 Preinstallation Information 2 Pump Performance Data 3 4 Electrical Data 5 Major Components 5 Pump Installation and Wiring Diagram 6 System Wiring Instructions 6 Splicing Underground Wires 7 Start up and Maintenance 7 Troubleshooting Service Checklist 7...

Страница 2: ...er sufficient voltage to the pump motor But more important they could present a safety hazard if the insulation were to become damaged or the connection end were to get wet 7 Make sure the pump electrical supply circuitisequippedwithfusesorcircuitbreakersofproper capacity A separate branch circuit is recommended and Limited Warranty Manufacturerwarrants tothepurchaserandsubsequentownerduring thewa...

Страница 3: ...401 ft 122 2m Liters Gal 3 4 HP 120 36 6 80 24 4 11 6 43 9 13 1 49 6 13 0 49 2 14 1 53 4 40 12 2 14 5 54 9 1 2 HP 7 STAGE 360 400 26 9 36 3 7 6 240 160 200 48 8 73 2 61 2 0 9 6 7 1 44 7 40 1 35 2 9 3 11 8 10 6 280 85 3 28 8 7 6 104 112 120 360 109 7 3 2 12 1 21 2 5 6 97 5 320 3 4 HP 10 STAGE 7 STAGE Liters 177 ft 54 0m 9 4 5 5 Gal 12 1 14 4 35 6 20 8 45 8 54 5 1 2 HP 5 STAGE 1 2 HP 5 STAGE 440 480...

Страница 4: ...2 3 35 9 Gal 135 9 129 5 122 3 Liters 3 4 HP 5 10 20 15 25 30 35 40 0 20 40 60 80 100 140 120 20 140 40 60 80 100 120 0 8 16 24 32 40 180 220 200 160 240 48 56 64 72 54 9 180 220 200 67 1 61 140 160 42 7 48 8 77 6 20 5 51 9 13 7 7 1 17 2 26 9 65 1 22 3 18 7 84 4 70 8 98 4 88 6 26 23 4 1 2 HP 4 STAGE 3 4 HP 6 STAGE 1 HP 7 STAGE 4 STAGE 6 STAGE 7 STAGE 129 8 124 5 120 4 Liters 137 4 141 6 311 Ft 94 ...

Страница 5: ...ine pumps are nonautomatic The use of float switches are required for the proper operation of the pump Operation of these pumps without float switches can result in failure of the pump and void the warranty A minimum of two float switches should be used in each application A pump control float switch A high water alarm float switch 4 Piping The submersible effluent turbine pump can be installed wi...

Страница 6: ...gram with the alarm for installation and check your local codes 9 Runtheappropriatepowertothecontrolpanelfromafused circuit breaker disconnect The appropriate power supply information may be found on the pump nameplate 10 To provide a suitable ground a separate ground wire green or bare at least as large as the line conductors is required It is connected from the electrical disconnect box to the c...

Страница 7: ...nections Make sure the weep hole is clear Make sure the float switches are free to move within the basin Make sure there are no leaks in the plumbing Make sure there is no excessive noise while the pump is running ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are not standing in water and wearing insulated protective ...

Страница 8: ...Manufacturers of www zoeller com Typical Installations ALL INSTALLATIONS REQUIRE A FILTER BEFORE THE PUMP SK2220 SK2219 ZOELLER EFFLUENT TURBINE PUMP WARNING P N Z ZOELLER SEPTIC TANK SEPTIC TANK ZOELLER EFFLUENT TURBINE PUMP WARNING ELECTRICAL SHOCK HAZARD Z C O Z P N 10 1193 REV A 0ELLER PUMP CO LOUISVILLE KY NOTE Flow must be directed around the motor for cooling on 2 HP and higher units ...