Limited Warranty

Manufacturer warrants, to the purchaser and subsequent owner during the 

warranty period, every new product to be free from defects in material and 

workmanship under normal use and service, when properly used and main-

tained, for a period of one year from date of purchase by the end user, or 18 

months from date of original manufacture of the product, whichever comes first.  

Parts that fail within the warranty period, one year from date of purchase by the 

end user, or 18 months from the date of original manufacture of the product, 

whichever comes first, that inspections determine to be defective in material or 

workmanship, will be repaired, replaced or remanufactured at Manufacturer's 

option, provided however, that by so doing we will not be obligated to replace 

an entire assembly, the entire mechanism or the complete unit.  No allowance 

will be made for shipping charges, damages, labor or other charges that may 

occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or act of 

God; that has not been installed, operated or maintained in accordance with 

Manufacturer's installation instructions; that has been exposed to outside 

substances including but not limited to the following:  sand, gravel, cement, 

mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, 

etc.), or other abrasive or corrosive substances, wash towels or feminine 

sanitary products, etc. in all pumping applications.  The warranty set out in 

the paragraph above is in lieu of all other warranties expressed or implied; 

and we do not authorize any representative or other person to assume for us 

any other liability in connection with our products.

Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, 

Attention: Customer Service Department to obtain any needed repair or replace-

ment of part(s) or additional information pertaining to our warranty.

MaNUfactUrer eXpressly DisclaiMs liaBility for special, 

coNseQUeNtial or iNciDeNtal DaMages or BreacH of eX-

presseD or iMplieD warraNty; aND aNy iMplieD warraNty 

of fitNess for a particUlar pUrpose aND of MercHaNt-

aBility sHall Be liMiteD to tHe DUratioN of tHe eXpresseD 

warraNty.

Some states do not allow limitations on the duration of an implied warranty, 

so the above limitation may not apply to you. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other 

rights which vary from state to state.

  1.  Read all instructions before beginning installation.

  2.  Be sure the installation does not exceed a maximum vertical lift of 16 feet 

(Model 108) or 21 feet (Model 138).

  3.  Be sure the basin is level within 1/8” across the diameter.

  4.  Do not over torque extension tank attachment bolts.

  5.  Use backfill gravel that is larger than the slots in the basin.

Ten Helpful Hints For Easy Installation

  6.  Test operation of pump per STEP 5.

  7.  Do not over tighten bushing, check valve, or hose clamp.

  8.  Plug pump into a properly grounded, constant voltage source.

  9.  Do not plug into a device that runs intermittently.

 10.  Obtain model number and date code prior to calling factory.

  1.  DO read all installation material included with the pump.

  2.  DO inspect unit for any visible damage caused by shipping. Contact dealer 

if unit appears to be damaged.

  3.  DO clean all debris from the pump reservoir.   

  4.  DO always disconnect pump from power source before handling. DO 

always connect to a separately protected and properly grounded ground 

fault protected circuit. DO NOT ever cut, splice or damage power cord. 

DO NOT carry or lift pump by its power cord. DO NOT use an extension 

cord with this Crawl Space Pumping System. 

Do’s  And  Don't’s  For  Installing  A  Unit

  5.  DO NOT use

 

a discharge pipe smaller than the diameter of the hose 

kit.

  6.  DO test pump immediately after installation to be sure that the system is 

working properly. 

  7.  DO review all applicable local and national codes and verify that the 

installation conforms to each of them. 

  8.  DO  inspect  and  test  system  for  proper  operations  at  least  every  3 

months. 

Содержание CRAWL SPACE 108

Страница 1: ... Pump Company is one of the oldest and largest pump manufacturers in the U S and has a history of supplying innovative products and services to its customers Through research and development design testing and manufacturing we have been able to bring products to the market that solve problems that plague consumers industry and the environment This commitment to our customers has enabled them to en...

Страница 2: ...r warranty MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EX PRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANT ABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Some states do not allow limitations on the duration of an implied warranty so the above limitation may not ap...

Страница 3: ...S 10 20 30 40 50 60 70 80 5 10 15 20 25 0 0 80 160 240 2 4 6 GALLONS LITERS FLOW PER MINUTE METERS FEET TOTAL DYNAMIC HEAD PUMP PERFORMANCE CURVE MODEL 98 009971 Model 108 Model 138 98 95 170 231 273 Liters 23 ft 7 0m Shut off Head 20 7 1 25 Meters 15 10 Feet 5 4 6 3 0 1 5 MODEL 61 72 Gal 45 19 25 ft 5 9m 53 Shut off Head MODEL 15 10 Feet 5 4 6 3 0 34 19 1 5 Meters 43 Gal 72 129 163 Liters 009897 ...

Страница 4: ...he site to the dimension shown in Figure 2 1 Note Ifweeptilesordrainlinesaretobeused rough inplumbing should be completed at this time 2 2 Lower basin into pit Refer to Figure 2 2 Complete instal lation of weep or drain lines STEP 2A Installation of Slotted Basin with Optional Extension Kit 2A 1 Excavate the site to the dimensions shown in Figure 2A 1 Note If weep tiles or drain lines are to be us...

Страница 5: ... WEEP TILES SLOTTED BASIN PRIMARY PUMP EXTENSION 1 1 4 ELECTRICAL ACCESS HOLE SLOTTED BASIN LID 2 FLEXIBLE DISCHARGE LINE HOLE DISCHARGE LINE SLOTTED BASIN DRAIN LINES OR WEEP TILES PRIMARY PUMP 25 CORD Copyright 2009 Zoeller Co All rights reserved STEP 3 Installation of Pump and Cover 3 1 Attach the flexible discharge hose to pump and lower into pit 3 2 Attach lid and complete discharge line conn...

Страница 6: ...5 2 Pour water through lid until pump comes on 5 3 Check all discharge line connections for leaks or obstructions 5 4 If the pump begins to short cycle as described in part C of the troubleshooting guide then it will be necessary to install a check valve in the discharge line This will prevent water from draining from the discharge line back into the pit Refer to Figure 5 1 If a check valveisinsta...

Страница 7: ...mp 1 012319 012320 2 Slotted Basin 1 012172 012172 3 Lid 1 012173 012173 4 Hose Kit 1 1010 0117 1010 0117 REF NO MODELS 108 A DESCRIPTION NOTES 138 A 6 98 to Present 6 98 to Present Accessories Item P N Description QTY 5 1010 0786 Extension Kit and Lid 1 6 10 0770 Weather Tight Junction Box 1 7 10 1494 Alarm 1 QTY sk1824 sk1823 sk1858 8 EXTENSION KIT AND LID WEATHER TIGHT JUNCTION BOX 5 6 ...

Страница 8: ... Authorized Service Station Remove debris as necessary Contact a Zoeller Authorized Service Station Clear weep hole as necessary Clear lines as necessary Refer to pump performance chart on page 3 or contact factory Have qualified electrician check circuit Clear and protect from freezing See STEP 6 Condition Possible Cause Remedy A PUMP WILL NOT START OR RUN B PUMP TRIPS OVERLOAD OR BLOWS FUSE C PU...

Отзывы: