THREE PHASE INSTALLATION

Three phase pumps are nonautomatic. To operate 

automatically, a control panel is required. Follow the 

instructions provided with the panel to wire the system.

Before installing a pump, check the pump rotation to insure 

that wiring has been connected properly to power source, 

and that the green lead of power cord (See wiring diagram), 

is connected to a valid ground, Momentarily energize the 

pump, observing the directions of kick back due to starting 

torque. Rotation is correct if kick back is in the opposite 

direction of rotation arrow on the pump casing. If rotation 

is not correct, switching of any two power leads other than 

ground, should provide the proper rotation.

Refer to wiring diagram supplied with specific electrical 

control panel for correct electrical cable termination 

locations.

NOTE 1: 

Sensor cable includes 5 leads; 2 leads for thermal sensor , 2 

leads for moisture sensor, and a green ground lead. Sensor wire colors 

are as shown.

(N/C)

SENSOR

330K OHMS RESISTANCE

SEAL FAILURE PROBES

PANEL.

INDUCTION CIRCUIT IN THE CONTROL

LEADS MUST BE CONNECTED TO 

SEAL FAILURE MOISTURE SENSOR

STARTER COIL

CONNECTED IN SERIES WITH

RECOMMENDED THERMAL SENSOR

THERMAL

T3

T2

T1

L3

L2

L1

POWER CABLE

3 PHASE MOTOR

3Ø VAC

SENSOR CABLE

BLACK

WHITE

ORANGE

RED

GREEN

TYPICAL 3-PHASE  WIRING DIAGRAM

Refer to Sensor Cable and Control Panel sections on page 5.

ZEPA0038E

SINGLE PHASE INSTALLATION (7110 & 7111 ONLY)

All single phase models require start capacitor, run capacitor and relay in the circuit to start and operate properly. These components can be purchased separately 

or prewired in a Zoeller control panel. For components purchased separately use the diagram for installation and hookup.
Single phase models are nonautomatic. To operate automatically a control panel  must be added to the power circuit. Follow the instructions provided with the panel.

WIRING DIAGRAM

COMPONENT LAYOUT

ZEPA0538

ZEPA0537C

2

1

5

WHITE

PUMP

START

MAIN

BLACK

L2

WHITE

BLACK

RUN CAPACITOR

RED

START CAPACITOR

L1

T2

T1

3

2

1

GREEN

230 VAC 1ø

(SEE CHART)

(SEE CHART)

7110/7111

MODELS

270-324UF 250V

START CAP.

RUN CAP.

50UF 370V

R

RELAY

START

5

2

1

WHITE

RED

PUMP

MAIN

START

L1

L2

BLACK

WHITE

230 VAC 1Ø

FROM CONTACTOR

START

BLACK

START

RELAY

CAPACITOR

RUN CAPACITOR

1

2

3

GREEN

Содержание 71 HD Series

Страница 1: ...rence ZM1788 for repair manual on 71 Series Grinder Pumps Should further assistance be necessary please call our Product Support Department at 1 800 928 PUMP 7867 TABLE OF CONTENTS Safety Instructions 1 Limited Warranty 2 Preinstallation Information 3 Electrical Data 3 Typical Sewage Installation 4 Pump Wiring Instructions 5 6 Operation 7 Maintenance 7 Service Checklist 8 SAFETY INSTRUCTIONS TOAVO...

Страница 2: ...CIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Some states do not allow limitations on the duration of an implied warranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation...

Страница 3: ...rding installation and use These materials should be retained for future reference 1 Do not lift carry or hang pump by the electrical cables Damage to the electrical cables can cause shock burns or death 2 Make sure there is a properly grounded connection available All pumps are furnished with provisions for proper grounding to help protect you against the possibility of electrical shock 3 Make ce...

Страница 4: ...15 Basin must be clean and free of debris after installation and before operation ZEPA0521 All installations must comply with all applicable electrical and plumbing codes including but not limitedto NationalElectricalCode local regional and or state plumbing codes etc 1 Electrical wiring and protection must be in accordance with the NationalElectricalCode andanyotherapplicablestateandlocal electri...

Страница 5: ...or continuity complete circuit with a Volt OHM Meter Set the VOM to read resistance and connect the VOM leads to the sensor cord black and white wires The VOM should read approximately 330k Ohms Resistance readings significantly lower indicates an entry of moisture into the pump If VOM reading is open then a problem exists with moisture detection circuit 3 The green wire shall be connected to a gr...

Страница 6: ...TION CIRCUIT IN THE CONTROL LEADS MUST BE CONNECTED TO SEAL FAILURE MOISTURE SENSOR STARTER COIL CONNECTED IN SERIES WITH RECOMMENDED THERMAL SENSOR THERMAL T3 T2 T1 L3 L2 L1 POWER CABLE 3 PHASE MOTOR 3Ø VAC SENSOR CABLE BLACK WHITE ORANGE RED GREEN TYPICAL 3 PHASE WIRING DIAGRAM Refer to Sensor Cable and Control Panel sections on page 5 ZEPA0038E SINGLE PHASE INSTALLATION 7110 7111 ONLY All singl...

Страница 7: ...emain in the pit With the pump in the pit it should be operated for five minutes once every three months If the pit is to remain wet the pump should be removed and stored as noted above Panels The panel should have all openings sealed to prevent moisture and dust from entering the enclosure Prior to restarting system the panel should be inspected for presence of moisture and any loose connections ...

Страница 8: ...or defective Pit too small D Pump will not shut off Debris clogging cutter plate Debris under float switch Float travel obstructed Defective or damaged float switch Magnetic starter contacts shorted Air lock check vent hole E Pump operates but delivers little or no water Check for plugged cutter pump housing pipe or sticking check valve Vent hole clogged or not drilled Discharge head exceeds pumps...

Отзывы: