2
© Copyright 2019 Zoeller
®
Co. All rights reserved.
Zoeller Pump Company warrants, to the purchaser and subsequent owner
during the warranty period, every new Zoeller Pump Company product
to be free from defects in material and workmanship under normal use
and service, when properly installed, used and maintained, for a period
of two years from date of purchase. Proof of purchase is required.
Parts that fail within the warranty period that inspections determine to
be defective in material or workmanship, will be repaired, replaced or
remanufactured at Zoeller Pump Company’s option, provided however,
that by so doing we will not be obligated to replace an entire assembly,
the entire mechanism or the complete unit. No allowance will be made
for shipping charges, damages, labor or other charges that may occur
due to product failure, repair or replacement.
This warranty does not apply to any material that has been disassembled
without prior approval of Zoeller Pump Company, subjected to misuse,
misapplication, neglect, alteration, accident or act of God; that has not
been installed, operated or maintained in accordance with Zoeller Pump
Company installation instructions; that has been exposed to but not
limited to the following: sand, gravel, cement, mud, tar, hydrocarbons
or hydrocarbon derivatives (oil, gasoline, solvents, etc), wash towels
or feminine sanitary products, etc. or other abrasive or corrosive
substances. This warranty is in lieu of all other warranties expressed
Limited Warranty
or implied; and we do not authorize any representative or other person
to assume for us any other liability in connection with our products.
Contact Zoeller Pump Company, 3649 Cane Run Road, Louisville, Kentucky
40211-1961, Attention: Customer Service Department to obtain any needed
repair or replacement of part(s) or additional information pertaining to
our warranty.
ZOELLER PUMP COMPANY EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR
A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED
TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty,
so the above limitation may not apply to you. Some states do not allow
the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have
other rights which vary from state to state.
1. Read all instructions before beginning installation.
2. Be sure the installation does not exceed a maximum of 15
feet of vertical lift.
3. Be sure the pump is level within 1/8" for the length of the
condensate pump.
4. Use soapy water when cleaning unit. Refer to maintenance
guidelines.
5. For best results, drain and discharge lines should have a
continuous downward slope.
1. DO read all installation material included with the pump.
2. DO inspect unit for any visible damage caused by shipping.
Contact dealer if unit appears to be damaged.
3. DO clean all debris from the pump reservoir.
4. DO always disconnect pump from power source before
handling. DO always connect to a separately protected and
properly grounded ground fault protected circuit. DO NOT
ever cut, splice or damage power cord. DO NOT carry or
lift pump by its power cord. DO NOT use an extension cord
with this condensate pump.
Ten Helpful Hints or Easy Installation
Do’s and Do Nots or Installing Unit
5. DO NOT use a discharge pipe smaller than the pump discharge
size.
6. DO test pump immediately after installation to be sure that
the system is working properly.
7. DO review all applicable local and national codes and verify
that the installation conforms to each of them.
8. Do not use Flexible tubing larger than 3/8".
6. Test operation of pump per STEP 5.
7. Do not overtighten check valve after cleaning. Refer to
maintenance guidelines.
8. Plug pump into a constant voltage source. Do not plug into
a device that runs intermittently.
9. The model number and date code can be found on the
pump I.D. label.
10. For best results, the highest point of the discharge line
should be higher than 5’ above floor.
In instances where property damages are incurred as a result of an alleged product failure, the property
owner must retain possession of the product for investigation purpose.