Zoeller Pump Company warrants, to the purchaser and subsequent owner 

during the warranty period, every new  Zoeller Pump Company product 

to be free from defects in material and workmanship under normal use 

and service, when properly installed, used and maintained, for a period 

of two years from date of purchase. Proof of purchase is required. 

Parts that fail within the warranty period that inspections determine to 

be defective in material or workmanship, will be repaired, replaced or 

remanufactured at Zoeller Pump Company’s  option, provided however, 

that by so doing we will not be obligated to replace an entire assembly, 

the entire mechanism or the complete unit. No allowance will be made 

for shipping charges, damages, labor or other charges that may occur 

due to product failure, repair or replacement.

This warranty does not apply to any material that has been disassembled 

without prior approval of Zoeller Pump Company, subjected to misuse, 

misapplication, neglect, alteration, accident or act of God; that has not 

been installed, operated or maintained in accordance with Zoeller Pump 

Company installation instructions; that has been exposed to but not 

limited to the following: sand, gravel, cement, mud, tar, hydrocarbons 

or hydrocarbon derivatives (oil, gasoline, solvents, etc), wash towels 

or feminine sanitary products, etc. or other abrasive or corrosive 

substances. This warranty is in lieu of all other warranties expressed 

Limited Warranty

or implied; and we do not authorize any representative or other person 

to assume for us any other liability in connection with our products.

Contact Zoeller Pump Company, 3649 Cane Run Road, Louisville, Kentucky 

40211-1961, Attention: Customer Service Department to obtain any needed 

repair or replacement of part(s) or additional information pertaining to 

our warranty.

ZOELLER PUMP COMPANY EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED 
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR 
A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED 
TO THE DURATION OF THE EXPRESSED   WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, 

so the above limitation may not apply to you. Some states do not allow 

the exclusion or limitation of incidental or consequential damages, so 

the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have 

other rights which vary from state to state.

  1.  Read all instructions before beginning installation.

                      

  2.  Be sure the installation does not exceed a maximum of 15 

feet of vertical lift.

                      

  3.  Be sure the pump is level within 1/8" for the length of the 

condensate pump.

  4.  Use soapy water when cleaning unit. Refer to maintenance 

guidelines.

                      

  5. For best results, drain and discharge lines should have a 

continuous downward slope.

  1.    DO  read  all  installation  material  included  with  the  pump.                                                      

                      

  2.  DO inspect unit for any visible damage caused by shipping. 

Contact dealer if unit appears to be damaged.              

                      

  3.  DO clean all debris from the pump reservoir.   

                      

  4.  DO always disconnect pump from power source before 

handling. DO always connect to a separately protected and 

properly grounded ground fault protected circuit. DO NOT 

ever cut, splice or damage power cord.  DO NOT carry or 

lift pump by its power cord. DO NOT use an extension cord 

with this condensate pump.     

Ten Helpful Hints or Easy Installation

Do’s and Do Nots or Installing Unit

  5.  DO NOT use a discharge pipe smaller than the pump discharge 

size. 

                      

  6.  DO test pump immediately after installation to be sure that 

the system is working properly. 

                      

  7.  DO review all applicable local and national codes and verify 

that the installation conforms to each of them.

 

8.   Do not use Flexible tubing larger than 3/8".

  6.  Test operation of pump per STEP 5.

  7. Do not overtighten check valve after cleaning. Refer to 

maintenance guidelines.

  8.  Plug pump into a constant voltage source. Do not plug into 

a device that runs intermittently.

  9. The model number and date code can be found on the 

pump I.D. label.

 10. For best results, the highest point of the discharge line 

should be higher than 5’ above floor.

In instances where property damages are incurred as a result of an alleged product failure, the property 

owner must retain possession of the product for investigation purpose.  

Содержание 522

Страница 1: ...ndusebeforeattemptingtheinstallation These materials should be retained for future reference 1 Check to be sure your power source is adequate to handle the amperage requirements of the motor as indica...

Страница 2: ...TED TO THE DURATION OF THE EXPRESSED WARRANTY Somestatesdonotallowlimitationsonthedurationofanimpliedwarranty so the above limitation may not apply to you Some states do not allow the exclusion or lim...

Страница 3: ...ownward slope to allow for gravity flow Note Local codes may require the use of a condensate neutralizer when using this pump Note Make sure the drain lines from the A C condenser are supported above...

Страница 4: ...9 STEP 3 Installation of Discharge Line STEP 4 Installation of Safety Switch TO MAIN DRAIN FLOOR JOISTS INVERTED U 3 8 ID TUBING PIPE SUPPORTS 15 FT MAX NOTE CONDENSATE DRAIN LINES NOT SHOWN REFER TO...

Страница 5: ...ould activate breaking the thermostat circuit to the appliance 4 Plug the pump in and allow the pump to empty the tank As the water level decreases the appliance will reset STEP 5 Testing of Pump Oper...

Страница 6: ...charge line s blocked Check drain line s and or discharge line for blockage B PUMP MAKES LOUD NOISES WHEN RUNNING Debris in reservoir Refer to Maintenance Guidelines section for cleaning instructions...