background image

© Copyright 2014 Zoeller Co. All rights reserved.

Содержание 135-0006

Страница 1: ...e for their safety 8 Risk of electrical shock Do not remove power supply cord and strain relief or connect conduit directly to the pump If the supply cable is damaged it must be replaced by an authorized Zoeller Representative 9 Pump contains oil which becomes pressurized and hot when operating Allow 2 hours after disconnecting before attempting service 10 Pump is not intended for potable water du...

Страница 2: ...eminine sanitary products or If the above checklist does not reveal the problem consult the factory Do not attempt to service or otherwise disassemble pump Service must be performed by an authorized Zoeller Company representative SERVICE CHECKLIST 1 DO read all installation material with the unit 2 DO inspect unit for any visible damage caused by shipping Contact dealer if unit appears to be damag...

Страница 3: ...e beginning installation 2 Be certain that basin is on a firm level surface 3 Do not use an automatic plumbing vent device 4 Do not over torque lid attachment screws 5 Always use a check valve on the discharge line 6 Test operation of pump per STEP 5 Ten Helpful Hints For Easy Installation 7 Always provide some means to disconnect basin from plumbing for maintenance purposes 8 Run unit at least on...

Страница 4: ...2002B BE SURE THAT WEEPHOLE IS NOT DIRECTED TOWARD THE FLOAT Water stream will be visible from this hole during pump run periods PIPING SHOWN ONLY FOR CLARITY DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE IMPORTANT STEP 3 Installation of the Foam Gasket 3 1 Install the foam gasket on to the gasket surface at the top of the basin refer to Figure 4 1 for details Figure 3 SK2368 GASKET SEAL DETAIL OVERLAP ...

Страница 5: ...y to basin using bolts nuts and washers supplied Do not over tighten 4 5 Attach a check valve to discharge pipe with flow away from pump To avoid unnecessary cycling check valve should be installed no more than 76 mm 3 above lid 4 6 Connect DN40 discharge pipe and DN50 vent pipe into existing house plumbing THE UNIT MUST BE VENTED Do not over tighten the discharge and vent pipe into the threaded c...

Страница 6: ...dard length cord 1 152134 N A N A N A Replacement pump U152 No Plug N A 152548 N A N A Replacement pump U152 G Plug 33 long cord N A N A 152549 N A Replacement pump U152 I Plug N A N A N A 152550 3 Basin Cover Seal 1 004597 4 Discharge Tube 1 013732 5 Hardware Pack 1 007725 6 Basin Seal 1 006302 7 Union Check valve Combo 1 30 0102 Notes 1 Hardware pack consists of foam seal 10 24 x 1 long screws 1...

Страница 7: ...er Co All rights reserved NOTES MAIL TO P O BOX 16347 Louisville KY 40256 0347 USA SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 USA 1 502 778 2731 1 800 928 7867 FAX 1 502 774 3624 visit our web site zoellerpumps com ...

Страница 8: ... Copyright 2014 Zoeller Co All rights reserved ...

Отзывы: