19
IL1288
Priming Plug with
Pressure Gauge
Water
Level
Pipe Tee
Closed
Open
5
6
5. Wait 10 minutes to see if water level drops
below the pipe tee. If level drops, check foot
valve. If level stays constant, replace the
priming plug.
6. Reconnect 1-1/2 in. union on outlet pipe.
Open the ball valve (turn handle to line up
with pipe), and then turn on breaker to start
pump.
Outlet Pipe
Open Union
Air Relief
Plug
Pipe Tee
4
4. Replace air relief plug and continue adding
water to pump cavity until water comes out of
the open outlet pipe at the open union.