DRAIN PUMP SYSTEM 

MODEL 105 (Korean)

 

INSTALLATION INSTRUCTIONS 

PREINSTALLATION CHECKLIST

 

FM3034_Ea

0717

Supersedes

New

Notice to Installer:  Instructions must remain with installation.

MODEL:_______________________

DATE CODE:  __________________

DATE INSTALLED:   _____________

1.   

Inspect your unit.

 Occasionally, products are damaged during shipment. If the unit is damaged, contact  your dealer before using.  DO NOT remove the test 

plugs from the pump. 

2.   

Carefully read the literature

 provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future 

reference. 

1.  To reduce the risk of electrical shock, a properly grounded receptacle of 

grounding type must be installed and protected by a ground fault circuit 

interrupter (GFCI) and in accordance with National Electrical Code and local 

codes. 

2.  Make certain that the receptacle is within the reach of the pump’s power 

supply cord. DO NOT USE AN EXTENSION CORD.  Extension cords that 

are too long or too light do not deliver sufficient voltage to the pump motor 

and could present a safety hazard if the insulation were to become damaged 

or the connection end were to fall into the sump.

3. 

Testing for Ground.

 As a safety measure, each electrical outlet should be 

checked for ground using an Underwriters Laboratory Listed circuit analyzer 

which will indicate if the power, neutral and ground wires are correctly con-

nected to your outlet. If they are not, call a qualified electrician.

4.  For Added Safety. Pump must be connected to a 3-prong grounded outlet 

interrupter device (ground fault circuit interrupter).

5.  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS 

POWER SOURCE BEFORE HANDLING.  Single phase pumps are supplied 

with a 3-prong grounded plug to help protect you against the possibility of 

electrical shock.  DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE 

GROUND PIN.  To reduce the risk of electrical shock, a properly grounded 

receptacle of grounding type  must be installed and protected by a ground 

fault circuit interrupter (GFCI) in accordance with national electrical code and 

local codes.

6.  Installation and checking of electrical circuits and hardware should only be 

performed by a qualified, licensed electrician. 

7.  Risk of electric shock - These pumps have not been investigated for use in 

swimming pool areas.

1.  Check to be sure your power source is adequate for handling the voltage 

requirements of the motor, as indicated on the pump or basin plate. 

2.  Make sure the pump electrical supply circuit is equipped with fuses or circuit 

breakers of proper capacity. A separate branch circuit is recommended, sized 

according to the National Electrical Code and local codes for the current 

shown on the pump name plate. 

3.  All plumbing (discharge and vent lines) must be installed to meet local codes. 

Unit must be vented. DO NOT USE AN AUTOMATIC PLUMBING VENT 

DEVICE SIMILAR TO A "PRO-VENT". Some states require this product to 

be installed by a licensed plumber.

4.  Repair and service should be performed by Zoeller Pump Company Authorized 

Service Station only.

5.  CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY CYCLING 

OF PUMP. 

6.  Dewatering pumps are not designed or intended for handling raw sewage. 

7.  Maximum operating temperature for 105 Drain Pumps must not exceed  

54 °C (130 °F).

8.  For health reasons, do not unplug, turn off, or disable pump and use pump 

tank system as a way to fill up a sink or laundry tray, etc.

9.  Unit is designed for above ground installation only.

SEE BELOW FOR LIST OF WARNINGS

CAUTION

SEE BELOW FOR LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

Notice to Installer:  Instructions must remain with installation.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:

  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL:

 (502) 778-2731 • 1 (800) 928-PUMP • 

FAX:

 (502) 774-3624

Visit our web site:

www.zoellerpumps.com

Your Peace of Mind is Our Top Priority

 

®

60 Hz

P/N 154927 

Содержание 105

Страница 1: ...o reduce the risk of electrical shock a properly grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter GFCI in accordance with national electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been in...

Страница 2: ...ow limitations on the duration of an implied warranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS...

Страница 3: ...ontact dealer if unit appears to be damaged 3 DO clean all debris from the basin and pump 4 DO always disconnect pump from power source before handling DO always connect to a separately protected and properly grounded ground fault protected circuit DO NOT ever cut splice or damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord Do s And Don t s For Installing A ...

Страница 4: ... side standard IMPORTANT Check local and state codes before using the internal trap option 1 1 Figure 1 1A and 1 1B are typical configurations for installation of the drain systems The actual configuration will vary depending on your cabinet and sink configuration NOTE If installing the internal trap record the x dimension it will be required in Step 4 INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS F...

Страница 5: ...ARD THE FLOAT Water stream will be visible from this hole during pump run periods IMPORTANT DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE SK2002 STEP 3 Installation of the Gasket 3 1 Install the gasket into the gasket seat at the top of the basin Figure 3 1 SK3160 OVERLAP DETAIL GASKET SEAT FOAM GASKET GASKET SEAT DETAIL FOAM GASKET APPROXIMATELY 1 4 OVERLAP BASIN ...

Страница 6: ...stallation Only 4 1 Cut the tailpipe to the dimension determined in Figure 4 1 4 2 Install the sink drain components to the lid as shown in Figure 4 2 4 3 Orient the lid assembly as shown in Figure 4 3 and secure the trap components HAND TIGHTEN the assembly to the lid at this time Adjustment will be required in Step 5 Note To ensure a proper water seal the extension must be installed as shown in ...

Страница 7: ...LATION STEP 5 Final Assembly NOTE External plumbing configuration will vary depending on the location of basin location of main stack and available space 5 1 Place the pump in the basin as shown in Figure 5 1 NOTE If installing the internal trap rotate the tail pipe to the orientation shown in Figure 5 1 5 2 Install the lid components as shown in Figure 5 2 NOTE Pull excess cordage through the ope...

Страница 8: ...13 2 Basin Tank 1 013017 013017 3 Discharge 1 013732 N A 4 Basin Lid 1 013018 013018 A 5 Hardware pack seal 1 154256 154256 6 Unicheck 1 30 0181 30 0181 Notes 1 Hardware pack consist of 8 1 4 20 x 1 1 8 long round head stainless steel machine screws 8 1 4 20 stainless steel hex nuts and 16 1 4 flat stainless steel washers along with 1 pipe cap and 1 o ring and 1 pipe seal Copyright 2017 Zoeller Co...

Отзывы: