Page 9
ZXC-SERIES™ | Installation and Operation Manual
9. Each inlet is fitted with a water deflector.
These deflectors must remain in place to
prevent damage to the filter due to high-
speed water flow from the pump (Figure 7).
NOTE:
Both inlet water deflectors are installed at the
factory.
Inlet
Deflectors
Figure 7. Water Deflectors
10. Install the drain cap assembly into drain port
(Figure 8).
O-Ring
Drain Filter
Lock Nut
Cap
Gasket
Figure 8. Drain Cap
11. Assemble the pressure gauge with front and
rear casings (Figure 9).
Front Casing
Rear Casing
Figure 9. Pressure Gauge Casings
12. Apply Teflon tape (not included) to the
pressure gauge and screw into lid where
indicated (Figure 10).
13. Install the air relief valve (also known as air
bleed valve) into the lid (Figure 10).
NOTE:
The air relief valve is fitted with an O-ring at the
factory. Make sure that the O-ring is on the air
relief valve, before installing into the lid.
Teflon Tape
Pressure Gauge
Air Relief
Valve
O-ring
Figure 10. Pressure Gauge and Air Relief Valve
Installation