H0430700.A - EN - 2014-05
6
EN
Keyboard lock/unlock:
Press
and
for 3 seconds:
or
2.2 Starting up the appliance
•
Check that there are no more tools or any other foreign objects in the machine,
•
The panel to access the technical part must be fitted,
•
The bypass and settings valves (see §1.4) must be positioned as follows:
-
valve 1 fully open,
-
valves 2, 3, 4 and 5 closed
Incorrect bypass settings can cause the heat pump to malfunction.
•
Start up water circulation,
•
Gradually shut off valve 1 to increase the filter pressure by 150g (0.150 bars),
•
Fully open valves 2, 3 and 4, then open valve 5 half way (see §1.4) (the air accumulated in the heat pump condenser
and the filtering circuit will be drained off),
If valves 4 and 5 are not present, open valve 2 fully and close valve 3 half way.
•
Turn on the heat pump electricity supply,
•
If the heat pump is on stand-by, press
, for 3 seconds, the start-up screen will display for 4 seconds, then the home
screen displays, a two minute count down will start.
Set the set point temperature:
• Press
to increase the temperature by 0.5 °C,
• Press
to lower the temperature by 0.5 °C,
When the pool reaches the required temperature, the heat pump stops automatically.
2.3 Menu presentation
To access the menu press
.
Menu
Description
Modes selection Choose the appliance operating mode (see §2.3.1)
Report
Read the sensor measurement values, the appliance operating speeds, and
the fault history (see §2.3.2)
Waterflow set
Reading for the presence of water flow (see §2.3.3)
Parameters
Read the appliance parameters (see §2.3.4)
Time setting
Set the appliance date and time (see §2.3.5)
Languages
Choose the interface language (see §2.3.6)
Contraste
Adjust the screen contrast (see §2.3.7)
2.3.1 Mode selection
Menu
Description
Boost
For a faster temperature rise
Smart
For optimised operation
Silence Eco
For economic and silent operation
Time slot
Define time ranges and operating modes
Cold mode
Water cooling function activated