ELECTRICAL HAZARD

• To reduce risk of electrical shock

– All electrical connections must be performed by a qualified electrician as per all applicable national, provincial, state or local

electrical codes.

– Make sure all electric power is off to pool equipment area prior to any installation or removal of Zodiac components.
– A clearly identified breaker must be installed in order to shut off electrical power to the heat pump in an emergency.
– Never open the electrical box without shutting off all power sources to the heat pump.
– If your heat pump features a water pump control option, do not forget to shut off the breaker to this water pump before servicing.

CHEMICAL USE HAZARD

• Improperly balanced water can grow bacteria and become a health concern, as well as damage your pool and its equipment.

Please have your water tested by a pool professional weekly.

• To avoid personal injury when working with pool chemicals, always wear rubber gloves and eye protection and work in a well-

ventilated area. Use caution when choosing a location to open and use chemicals as they may damage any surface in which they
come in contact.

EQUIPMENT WATER PRESSURE HAZARD

• Your pump/filter system is operated under pressure and the pressure must be released before you begin work. Please see your

pump/filter owner’s manual for further instructions.

PREVENT CHILD INJURY AND DROWNING

• To reduce the risk of injury, do not permit children to operate this product.
• Do not let anyone, especially small children, sit, step, lean, or climb on any equipment installed as part of your pool’s operational

system. Unless otherwise stated, ALL components of your pool's operational system should be located at least 3 feet from the
pool so children cannot use the equipment to gain access and be injured or drown.

WARNING

Failure to heed the following warnings can result in permanent injury, electrocution or drowning.

!

MANDATORY SAFETY INSTRUCTIONS

Congratulations on your purchase of a Zodiac Heat Pump! Your new heat pump from Zodiac will extend your swimming season
and provide you years of pool comfort and pleasure.
This manual will help you answer questions you may have, provide technical support, and allow you to safely enjoy your new Zodiac
Heat Pump. Please take a few moments to read through the entire manual.

IMPORTANT: YOUR HEAT PUMP MUST BE INSTALLED BY A

QUALIFIED ELECTRICIAN

READ AND FOLLOW ALL INSTRUCTIONS. 

• Thermodynamical and electrical characteristics are indicated on the number plate.
• Voltage requirements for the ZHP-3216-TI, ZHP-80-TI and ZHP-65-TI heat pump are 220V – make sure you connect to a

proper electrical source.

• Make sure there are no sprinkler heads near or directed at the heat pump. Most sprinklers are connected to wells which

contain minerals, sulphur and other aggressive contaminates in the water.These contaminates can cause corrosion and affect the
heat pumps efficiency.

• Do not place any chemicals directly into the skimmer. Doing so may cause damage to the heat exchanger. Chemicals should be

poured slowly into the pool in front of the return inlet to be dispersed evenly throughout the pool.

SAVE ALL INSTRUCTIONS.

CAUTION

Failure to heed the following warnings could cause damage to pool equipment.

!

F

AILURE TO FOLLOW INSTRUCTIONS WILL VOID YOUR WARRANTY

.

ELECTRICAL WARNINGS

• Electrical installations must be performed by qualified electricians only. Installation made by unqualified persons can result in

hazards to the installer and others.

• The electrical installation must conform to the most current version of the National Electrical Code, NFPA No. 70, and all

applicable local and state codes.

!

WARNING

Prevent injury from electrical current.

!

Содержание ZHP-3216-TI

Страница 1: ...ZHP 3216 TI ZHP 80 TI ZHP 65 TI TITANIUM SERIES HEAT PUMPS USER S MANUAL INSTALLATION MANUAL W235611 rev 2 2005 2006...

Страница 2: ...se the equipment to gain access and be injured or drown WARNING Failure to heed the following warnings can result in permanent injury electrocution or drowning MANDATORY SAFETY INSTRUCTIONS Congratula...

Страница 3: ...Flow Rates Basic Connection Chlorinators Brominators and Other Automatic Systems Off Line Chlorinator or Brominator Salt Chlorinator Multiple Unit Connection IV Maintenance p 8 Cleaning Winterizing Ti...

Страница 4: ...ou will get that dollar multiplied by the COP factor back in total dollars worth of pool heat As an example the Zodiac ZHP 3216 TI with one of the higher COP s in the industry at 6 4 yields 6 40 worth...

Страница 5: ...g fan 4 feet 4 facing service panel 2 feet Objects should be placed as far as possible from where the air is discharged IMPORTANT Your heat pump must have sufficient clearance to properly function Oth...

Страница 6: ...nt detail see plumbing schematic below 6 MODEL MINIMUM IDEAL MAXIMUM ZHP 3216 TI 30 GPM 35 GPM 70 GPM ZHP 80 TI 30 GPM 35 GPM 70 GPM ZHP 65 TI 20 GPM 35 GPM 70 GPM ZHP 3216 TI ZHP 80 TI ZHP 65 Ti Top...

Страница 7: ...be installed as the last component on the pool return line the heat pump must be installed before the chlorinator or the warranty will be void Salt levels used with salt chlorinators will not harm ti...

Страница 8: ...ze the heat pump you must 1 Turn off the unit 2 Shut off the breaker of the heat pump electrical supply line 3 Disconnect the water inlet and outlet connections Figure A 4 Freely flush the condenser 5...

Страница 9: ...ity of the water to cause the degradation of metal is directly related to it Total alkalinity is the measure of the capacity of water to resist pH variation therefore it is also very important How to...

Страница 10: ...er acidity Acid water is often very clear because it is free of microorganisms but it can be unbalanced and become corrosive Sodium hypochlorite liquid chlorine Liquid chlorine is completely soluble i...

Страница 11: ...occurs when the selection label is no more shown on display SET In the MENU function it is used to set the selected parameter value and to enter the password In the STATUS function SET will be presse...

Страница 12: ...ualified electrician to take advantage of this feature Your installer will explain how the override works for your pool POWERED CARD Icon The POWERED CARD icon comes on when there is power to the unit...

Страница 13: ...w high pressure flow switch outputs are considered as enabled alarm start if contacts are open In case of alarm outputs will be controlled as shown in the following table LABEL Alarm description Reset...

Страница 14: ...recise its box is not and the thermometer may not be in line with the graduations written on the box In this condition the thermometer reads a temperature higher or lower than the real pool temperatur...

Страница 15: ...hours We will not be responsible for labor charges under this agreement if there were no defective parts Owner The warranty service agreement remains in effect as long as the product remains at the or...

Страница 16: ...on and adjustment of items such as evaporators condensers or air exchangers You must provide reasonable access to the unit s for servicing at all times Any work required to restore the property after...

Страница 17: ...ZODIAC POOL CARE INC 2028 N W 25th Avenue Pompano Beach FL 33069 1 800 830 4808 www zodiacpoolcare com CUSTOMER SERVICE info zodiacpoolheating com...

Отзывы: