17
4.3 I Additional menus
• From the home screen, press
to access the menus.
•
Press
to scroll through the menus.
Pool water temperature
Pool water temperature setpoint (SP = Set Point)
Dehumidifier heating water inlet temperature
Dehumidifier heating water temperature setpoint
Compressor status (ON = in operation / OFF = stopped)
Evaporator temperature
Defrost mode activation temperature
Defrost status (ON = in operation / OFF = stopped)
Countdown settings before defrost starts (60 seconds)
•
Defrost mode will be activated if the evaporator temperature is less than
or equal to the activation temperature for a period of 60 seconds.
Defrosting is carried out by reversal of the cooling cycle.
Defrosting ends if:
•
The defrost period (the machine setting can not be changed
by the user) has elapsed (600 seconds).
•
The temperature of the evaporator rises above a given
temperature (the machine setting can not be changed by the
user). This temperature is 10°C.
Evaporator temperature
Fan status (ON = in operation / OFF = stopped)
Ignore
Filtration status (ON = in operation / OFF = stopped)
Circulating pump status (ON = in operation / OFF = stopped)
The circulating pump only operates in the dehumidifier water
heating configuration.
Electric heater status (ON = in operation / OFF = stopped)
Ignore
Ignore
Ignore
Outside air temperature (ambient air) (ST1)
Pool water temperature (ST2)
Evaporator temperature (ST3)
Dehumidifier heating water inlet temperature (ST7)
Dehumidifier heating water outlet temperature (ST8)
Ignore