5. Troubleshooting
• Before you contact your reseller, please carry out these few simple checks using the following table if a
problem occurs.
• If the problem conti nues contact your reseller.
•
: Acti ons reserved for a qualifi ed technician
Message
Possible causes
Soluti ons
CHECK SALT
(orange “SALT”
indicator on)
•
Pool water temperature too low (< 18 °C,
variable).
•
Lack of salt (< 4g/L or 2.2 g/L in
accordance with the model) due to water
loss or diluti on (fi lter counterwash, water
renewal, rain, leaks, etc.).
•
Can vary depending on the temperature
and age of the cell. The voltage across
the cell terminals varies in ti me.
•
Basic producti on limitati on signal when the
water is too cold. Reduce
disinfectant producti on
or add salt to compensate.
•
Add salt to the pool to keep the level at
4 g/l or 2,2 g/L in accordance with the
model : see “1.2 Technical specifi cati ons”.
If you do not know the salt level or how to test it,
consult your reseller.
CHECK CELL
•
Calcium carbonate level (HL) too high
• Electrode too old
• Scaled cell
•
Clean and/or check the fi ltering system (pump
and fi lter)
•
Check the calcium carbonate levels (HL) and
add calcium carbonate sequestrant if necessary
(Calci-)
• Replace the electrode :
•
Clean the cell
PUMP FLOW
CONTROLLER FAULT
(“Flow” indicator
red and lit)
The messages
are displayed
alternati vely every
3 minutes.
•
Failure of the fi ltering pump
•
The fi lter and/or the skimmer(s) are dirty
• By-pass valves closed
• Flow controller and/or cell disconnected
or defecti ve
•
Check the pump, the fi lter, the skimmer(s), and
the by-pass valves. Clean them if necessary
•
Check the cable connecti ons (cell and fl ow
controller)
•
Check that the fl ow controller is working correctly
(replace it if necessary :
)
PROD. FAULT
•
Cell power supply cable disconnected or
not properly connected
• Internal electronic problem in the
control box following an external electric
incident
•
Switch off the chlorinator (
butt on) and
switch off the power supply to the control box,
then check that all the cables are properly
connected (mains power supply, cell, etc.)
INVERSION
•
The self-cleaning cycle is automati c; this
message is not an error code but an in-
formati on message
•
Wait for about 10 minutes and disinfectant
pro-
ducti on will resume automati cally at the previ-
ously set level
If the problem conti nues contact your reseller
.
To cancel the “CHECK CELL” and “PROD. FAULT” error messages, press
for 3 or 4 seconds on when the
message appears.
The other codes are only informati on messages that disappear automati cally when the operati ng conditi ons
return to opti mal.