5
5. USE OF THE CONTROL DISPLAY
5.1 Presentation
The “Bazic” control unit fitted in the front side is equipped with:
-
a digital display of 2 digits
(1),
to display the current and required pool’s
temperatures,
-
two sensitive switches to adjust the required temperature
(2),
-
a sensitive “on/off” switch
(3),
-
an “on/off” led
(“on”: led green)(4),
-
an operation state led
(5),
=> while heating:
fix led,
=> temporisation in process:
blinking led
Comments
: the adjustment range of the set point varies between 2° and 40°C*. This maximum temperature may
be decreased in order to protect the swimming pool liner, or it may be increased for specific purposes.
* the temperature is adjusted to the nearest °C assymetrically.
In order to change this maximum set point, access the menu “parameters” and change the parameter
"
r2
":
1) turn the regulator switch off, the "
on
" light goes off and the water temperature of the pool is
displayed,
2) press the
and
keys simultaneously for five seconds until “PA” is displayed,
3) press the key to re-enter the number
80
, the access code for the
menu “parameters”,
using
the
or
keys,
4) press the key to validate this code; “PA” is displayed,
5) press the
and
keys simultaneously for five seconds,
6) press the
key to view each parameter until “r2” is displayed,
Note: in order to display the parameter value "r2", press the key
, then to change it, press
the
or
key.
Important
!
Press the
key in order to validate this new setting.
7) press the
and
keys simultaneously to return to the pool water temperature display screen.
5.2 Setting of the temperature
The temperature is set by means of the sensitive keys
(2)
Display the value of the required temperature by pushing either
or
key.
Remark:
keeping one of these two buttons pressed makes it possible to go into fast search for the desired water
temperature value.
Single-phase power supply connection
Filtration
electric box
Three-phase power supply connection
Heater terminal
strip
Protection with 30 mA differential
circuit breaker at line head
Phase Neutral
Earth
For the power cabl’s cross section,
see table
Single-phase power supply: 230Vac (S terminal) + Neutral (C
terminal) + Earth
Three-phase power supply: 400Vac (R-S-T terminals) + Neutral (N
terminal) + Earth
Heater terminal
strip
Protection with 30 mA differential
circuit breaker at line head
Phases Neutral
Earth
For the power cabl’s cross section,
see table
Filtration
electric box
3
2
1
4
5
shunts
GB