![Zodiac Pac Alpha 5M Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/zodiac/pac-alpha-5m/pac-alpha-5m_instructions-for-installtion-and-use_4017704014.webp)
H04019
‐
00.A3.EN
–
2013/01
3
1.4
Technical
specifications
Pac
Alpha
5M
7M
9M
11M
Single
phase
voltage
230V
‐
50Hz
Power
consumption*
kW
0.98
1.56
2.06
2.6
Power
restored*
kW
4.65
6.52
8.6
10.5
Nominal
current
consumption*
A
4.45
7.09
9.36
12.4
COP*
4.7
4.2
4.2
4.1
Sound
power
dBA
65.4
66.7
69
72
Sound
pressure
at
10
meters
dBA
37.4
38.7
41
44
Protection
calibre
A
16
*
with
an
ambient
air
of
+15
°C
and
a
pool
water
of
24
°C,
humidity
70%
unit
protection
class:
IP
24
refrigerant
gas:
R410A
refrigerant
charge:
see
product
information
plate
2.
Installation
Do
not
pick
up
the
unit
using
the
outer
casing,
use
the
base
to
lift
and
move
the
unit.
2.1
Selecting
an
installation
site
The
appliance
must
be
installed
outdoors
and
there
must
be
adequate
open
space
surrounding
it
(see
§2.4).
The
heat
pump
must
be
installed
at
a
minimum
distance
from
the
end
of
the
pool
so
as
to
avoid
exposure
to
water
splashes.
The
appropriate
distance
should
be
defined
with
reference
to
the
national
electrical
standards
that
apply
in
the
country
of
installation
(in
France:
3.5
meters).
The
heat
pump
must
not
be
installed:
-
near
a
heat
source
or
near
inflammable
gas,
-
near
a
road
with
a
risk
of
water
and
mud
splashes,
-
facing
strong
wind,
-
with
the
vent
facing
toward
a
permanent
or
temporary
obstacle
(window,
wall,
hedge,
etc…),
it
must
be
at
least
3meters
from
such.
2.2
Installing
the
appliance
place
onto
a
stable,
solid
(concrete
slab
type)
and
level
surface,
protect
from
risks
of
flooding
due
to
condensation
produced
by
the
appliance
whilst
it
is
operating
(see
§2.4).
It
is
possible
to
fix
the
appliance
to
the
ground
using
the
holes
in
the
base
of
the
appliance
(fixings
not
supplied).
A
drilling
explanation
diagram
is
available
on
the
rear
of
the
packaging
box.
2.3
Hydraulic
connections
Respect
the
direction
of
the
hydraulic
connection
(see
§
"Dimensions"
in
the
appendix).
The
connection
uses
a
Ø40
pipe,
with
½
union
fittings,
on
the
pool
filtering
circuit,
after
the
filter
and
before
water
treatment
.
It
is
possible
to
connect
using
Ø32/Ø38
or
Ø50,
using
the
supplied
adapters,
Installing
a
bypass
is
mandatory
and
makes
interventions
on
the
appliance
easier,
Adjust
the
water
flow
rate
using
valve
VB,
and
keep
valves
VE
and
VS
open,
check
the
tightening
of
the
hydraulic
connections,
and
for
leaks.
Fixing
holes
ML1_Pac Alpha Ed 01-2013-noir.indd 14
16/01/13 11:05