Page 27
ENGLISH
Installation and Operation Manual
|
Jandy
®
LXi
™
Model Pool and Spa Heater by Zodiac
®
6.5.1 Connection to a Remote
Pool-Off-Spa Selector (3-Wire
Connection)
6.5.1.1 Install the Remote Pool-Off-Spa
Selector
1. Turn off the power to both the pool/spa control
system and the heater unit.
2. Remove the front panel door from the front of the
heater to access the raceway.
3. Run the wires from the pool/spa control system
through the opening, located on the lower right or
left hand side of the heater.
4. Connect the wiring from the pool/spa control sys-
tem to the heater remote control terminal.
See Figure 25.
5. Restore power to the heater and the pool/spa
control system.
6.5.1.2 Configure the Control Panel
1. Make sure the control is in the
OFF
mode.
2. To enter the Service Setup mode, press and hold
the
MENU
button and then the
POOL
and
SPA
buttons for 5 seconds.
NOTE
The display will revert back to OFF after 1
minute since the last key press.
3. Press the Up or Down button to display
RE-
MOTE
. Press the
MENU
button. The
SELECT
REMOTE OFF
(default remote) appears. Use the
Up or Down button to scroll through the Remote
options. When you reach
HI-LO-COM
, press the
MENU
button to select the remote. Press
POOL
or
SPA
to exit Service Setup mode.
6.5.2 Connection to an AquaLink
®
RS Control System or Remote
TSTAT (2-Wire Connection)
An interrupt (on/off) type remote can be connect-
ed as a Remote TSTAT, as described in this section.
This type of remote control will turn the heater on or
off, but will not perform any other function.
This type of connection may be used to connect
a Zodiac AquaLink RS Control System using any revi-
sion level programmed control chip. The control will
automatically turn the heater on and off and will dis-
play the pool water temperature, but all other function-
ality and display information will be inactive. When
using this type of connection, remember to set the LXi
heater's control to “SPA” and set the thermostat control
to maximum.
Consult with the Zodiac Pool Systems, Inc. Tech-
nical Support Department, 800.822.7933, for questions
about installing non-Zodiac remote controls.
6.5.2.1 Install the Remote TSTAT
1. Turn off the power to both the pool/spa control
system and the heater unit.
2. Remove the front panel door from the front of the
heater to access the raceway.
3. Run the wires from the pool/spa control system
through the opening, located on the lower right or
left hand side of the heater.
4. Connect the wiring from the pool/spa control
system to the heater remote control terminal. See
Figure 26.
5. Restore power to the heater and the pool/spa
control system.
Figure 25. Remote Pool-Off-Spa Connection (3-Wire
Connection)
Figure 26. AquaLink
®
RS or Remote TSTAT Connection
(2-Wire Connection)